Event
Motions of bench worker
Removing DIPS from plastic tube
Removing DIPS from vinyl tray
Removing DIPS from Styrofoam
Removing bubble pack from PCB
Packing PCBs in foam-lined box
14
Chapter 4 Removal and replacement preliminary requirements
Typical electrostatic voltage levels
10%
6,000 V
2,000 V
11,500 V
14,500 V
26,500 V
21,000 V
Relative humidity
40%
800 V
700 V
4,000 V
2,000 V
5,000 V
3,500 V
20,000 V
7,000 V
11,000 V
5,000 V
55%
400 V
400 V