Mitsubishi Electric Q26UD(E)HCPU User Manual page 214

Melsecq series
Hide thumbs Also See for Q26UD(E)HCPU:
Table of Contents

Advertisement

Item
Mounting position
Number of occupied points
Input voltage
Input frequency
Max. input apparent power
Inrush current
+15VDC
Rated output
current
-15VDC
Overcurrent
+15VDC
*1
protection
-15VDC
Efficiency
Power indicator
Power ON output
Terminal screw size
Applicable wire size
Solderless terminal
Applicable tightening torque
H
External
W
dimensions
D
Weight
*1
The overcurrent protection shuts off the +15VDC circuit if a current higher than the specified value flows in the circuit
and:
• Both +15VDC and -15VDC are switched off if overcurrent has occurred at +15V; or
• -15VDC is switched off but +15V remains output if overcurrent has occurred at -15V; and
• The power supply module LED is switched off or dimly lit due to ±15VDC voltage drop.
If this device is activated, turn off the input power supply and eliminate the cause such as insufficient current capacity
or short before restarting the system.
212
Performance Specifications
Power LED display (Normal: On (green), error: Off)
Switched on if +15V DC output is +14.25V or higher or -15V DC output is -14.25V or lower.
Min. contact switching load: 5V DC, 10mA
Min. contact switching load: 264V AC (R load)
V1.25 - 4, V2 - YS4A, V2 - S4, V2 - YS4A
A68P
I/O module slot
2 slots occupied, 1 slot 16 points
+10%
100 to 120V AC
-15%
(85 to 132V AC)
+10%
200 to 240V AC
-15%
(170 to 264V AC)
50/60Hz ±5%
95VA
20A, within 8ms
1.2A
0.7A
1.64A or more
0.94A or more
65% or more
Contact output
M3 × 0.5 × 6
2
0.75 to 2mm
68N•cm
250mm
75.5mm
121mm
0.9kg