Parameter P81: Forced Open Operation Judgment Time In Fault Close Operation; Setting Value Of Door Width (Parameter D01) - Panasonic AAD03011 Instruction Manual

Elevator door controller
Table of Contents

Advertisement

Parameter P81: Forced OPEN operation judgment time in fault CLOSE operation

When setting value of P80 is 1 or 2 , this parameter may be used to set obstacle detect
function (time detect) of the door in fault CLOSE operation. If fault CLOSE operation time from
start to CLOSE arrival exceeds setting valueof Parameter P81, obstacle detect is judged to
occur and the door is forced to carry out fault OPEN operation. This parameter may be used
to set validity or invalidity of function and judgment time of time detect.
Data setting range (ms)
If 0 is set to be, it indicates no obstacle detection function.
Setting value of door width(Parameter d01)
When the door width measurement is over, the door width data will be
automatically saved in parameter d01.
(See page 76, " supplementary explanation of door width measurement")
Data setting range
Note1) Door width data on the operation panel displays as follows.
When the door width data is 1 to 999, measurement data will be displayed directly.
When the door width data is more than 1000, the first three digits will be displayed.
(The last two digits will not be displayed.)
Example:
Door width data "65535" displays
Note 2) Using operation panel to directly set parameter d01(door width setting value),
the display value is the door width data. ( The data which is not displayed has
been cancelled.)
CLOSE and OPEN ARRIVAL POSITION (Parameter d02 and d08)
OPEN and CLOSE SPEED CHANGE POSITION 1 to 5
(Parameter d03 to d07 and d09 to d13)
CLOSE and OPEN ARRIVAL HOLD FREQUENCY( Parameter d14 and d21)
OPEN and CLOSE FREQUENCY 1 to 6 (Parameter d15 to d20 and d22 to d27)
OPEN and CLOSE ACCELERATION/DECELERATION TIME 1 to 6
(Parameter d28 to d33 and d34 to d39)
HOLD CURRENT DURING OPEN and CLOSE (Parameter d40 and d41)
OPEN/CLOSE HOLD OPERATION STOP TIME (Parameter d42)
OPEN and CLOSE ARRIVAL HOLD WAIT FREQUENCY( Parameter d43 and d44)
OPEN and CLOSE ARRIVAL HOLD WAIT TIME (Parameter d45 and d46)
OPEN and CLOSE START and DECELERATION TIMER (SW MODE)
(Parameter d47 to d50)
For data setting, refer to Page 39.
!
NOTE
The inverter can be easily set the operation from low speed to high speed.
Start the operation after ensuring the tolerance range of motor
and machinery.
Failure to do so could lead to injury.
When the brake is required to be held, other preparation should be made.
Failure to do so could lead to injury.
Used to set parameter of door control operation mode.
OPEN operation mode and CLOSE operation mode can be set independently.
The selection of encoder mode and SW mode is set with parameter P09.
66
500
1 to 65535
"655."