OVERLOAD DETECTION FREQUENCY 1, 2 (Parameter P59 and P60)

OVERLOAD DETECTION CURRENT1, 2 (Parameter P61 and P62)

OVERLOAD DETECTION JUDGMENT TIME (Parameter P63)

Caution
Apply obstacle detection function of the automatic door after security
and function operation of the lift is completely confirmed.
Failure to do so could lead to injury.
Safety sensor must be input in the main controller of the lift, and in
the terminal of the main controller, operate the obstacle detection
of the automatic door.
obstacle detection function of the inverter does not operate in
CLOSE arrival area.
Dual security measures must be taken.
Failure to do so could lead to injury.
Used to set the parameter of obstacle detection function(current detection)
of the automatic door.
If motor overload is detected by current and reach obstacle judgment level, the
automatic door will carry out the fault ON operation.
Used to set validity of function, current detection level detected by overload and
detection judgment time with these parameters.
(See page 73, the "supplementary explanation of obstacle detection function".)
Parameter
Function name
No.
P59
Overload detection frequency 1
P60
Overload detection frequency 2
P61
Overload detection current 1
P62
Overload detection current 2
P63
Overload detection judgment time
P62
Detection
range
P61
P59
Frequency
Current
detection level
P60
Data setting value
0.5 to 250 Hz
0.5 to 250 Hz
0.1 to 100 A
0.1 to 100 A
0 1 to 999 ms ("0" is set to no obstacle
detection function.)
Current detection level is set with the four
setting values of P59 to P62.
If the output current is higher than current
detection level, sandwich of automatic door is
judged and the automatic door carries out
fault ON operation.
The judgment time for obstacle detection can
be set with parameter P63.