Tml8W (Not For U.s.); Figure 3-126 Tml8W (Not For U.s.) (S30817-Q626-Axxx, -Bxxx) - Siemens HiPath 5000 Service Manual

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

3.3.39

TML8W (Not for U.S.)

Introduction
A TML8W (Trunk Module Loop Start World) board connects up to eight analog trunks for Hi-
Path 3750 and HiPath 3700 using the loop-start protocol.
The jumpers on the TML8W must be adjusted for call detail recording with a
Jumpers on TML8W
On
1
Lockout switch S100
:
(factory default)
:
8
H100 (green)
H101 (red)
Jumpers
(only avail-
able on
specific
board
variants)
Figure 3-126
TML8W (Not for U.S.) (S30817-Q626-Axxx, -Bxxx)
For Austria only: If a ÜFS trunk is connected to the TML8W, remove the jumpers
>
(W300 to W650) to activate silent reversal.
If silent reversal is inactive, users in the HiPath 3750 and HiPath 3700 would hear a
busy signal following backward release instead of being released.
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
LEDs
Jumpers
W700
W703
W706
W709
W800
W803
W806
W809
Jumpers
Inserted
(Circuit)
W700 (1)
W703 (2)
Yes
W706 (3)
W709 (4)
W800 (5)
W803 (6)
No
W806 (7)
W809 (8)
W650 (8)
W600 (7)
Yes
W550 (6)
W500 (5)
W450 (4)
W400 (3)
No
W350 (2)
W300 (1)
Factory default = All jumpers inserted
boards.fm
Boards for HiPath 3000
Peripheral Boards
GEE8
subboard.
Call Detail Record-
ing (GEE8)
16 kHz/50 Hz
12 kHz
Without
silent reversal
with
silent reversal
3-313