Communication Setup Menu - Bosch MIC612 Operation Manual

Hide thumbs Also See for MIC612:
Table of Contents

Advertisement

MIC612 Thermal Camera
8.6

Communication Setup Menu

The Communication Setup Menu contains baud rate and Bilinx control settings.
* AutoBaud:
* Baud Rate:
AutoBaud
Turns on AutoBaud detection, which detects and adjusts the camera protocol and baud rate to
match that of the controller. Options: ON (default setting), OFF. ON automatically accepts
baud rates from 2400 to 57600.
Note: If stepping from 2400 to 57600 baud, you must first set the Baud Rate to 19200 for
AutoBaud to detect the higher baud rate.
Baud Rate
Manually sets the baud rate when AutoBaud is set to OFF. Options are 2400, 4800, 9600
(default setting), 19200, 38400, and 57600.
Bilinx
Activates Bilinx control communication. (Only available when not connected to a Bilinx data
interface unit.) Options: ON (default setting), OFF.
Bosch Security Systems
Communication Setup
Exit...
Bilinx
Restore Defaults
* = Factory Setting
Focus / Iris: Select
On-Screen Display (OSD) Menus (Bosch Protocol) | en
ON
9600
Operation Manual
51
2016.03 | 2.1 | F.01U.249.416

Advertisement

Table of Contents
loading

Table of Contents