Fuser / Exit Unit; Pressure Roller Unit / Fuser Roller Unit - Toshiba e-STUDIO182 Service Manual

Hide thumbs Also See for e-STUDIO182:
Table of Contents

Advertisement

12.6.1

Fuser / Exit unit

(1)
Take off the right rear cover.
P.2-21 "2.5.10 Rear cover"
(2)
Lay down the transfer unit.
(3)
Disconnect 3 connectors, remove 2 screws,
and then take off the fuser/paper exit unit.
Note:
Be careful because the fuser/paper exit unit
is hot.
12.6.2

Pressure roller unit / Fuser roller unit

(1)
Take off the fuser/paper exit unit.
P.12-14 "12.6.1 Fuser / Exit unit"
(2)
Remove 1 spring and 2 screws.
(3)
Separate the pressure roller unit from the
fuser roller unit.
Note:
If the ADU (optional) is installed, the spring
has already been removed.
Note:
Separate the pressure roller and the heat
roller while pressing the thermistor ground
leaf spring.
e-STUDIO182/212/242
FUSER / EXIT UNIT
Fuser/ Paper exit unit
Fuser roller unit
© 2009 TOSHIBA TEC CORPORATION All rights reserved
12 - 14
Connector
Screw
Stepped screw
Fig. 12-9
Spring
Pressure roller unit
Fig. 12-10
Thermistor ground leaf spring
Fig. 12-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio212E-studio242

Table of Contents