The Problem Solver
Professional
Island Range Hood
Questions?
Use this
problem
solver!
PROBLEM
POSSIBLE CAUSE
FAN AND LIGHTS DO
NOT OPERATEWHEN
THE SWITCHESARE
TURNED ON
e
THE BLOWER DOES
NOT WORK BUT
THE LIGHTS DO
2.
3.
4.
THE BLOWER FAILS
TO EXHAUSTTHE
i.
SMOKE/STEAM/
ODORS ADEQUATELY
2.
3.
4.
5.
6.
The hood was never electricallg connected bg the installer/
electrician/builder. Call the electrician/installer/builder
to
complete the installation. This is not covered bg warrantg.
A fuse mag be blown or a circuit breaker tripped. Replace the fuse
or reset the circuit breaker.
The blower motor wire harness was not connected or was not
connected properlg bg the installer/electrician/builder
to its mating
connector located inside the hood on the top surface, to the left of
the blower assemblg.
1. Switch power off at service panel and lock the service disconnecting
means to prevent power from being switched on accidentallg. When
the service disconnecting means cannot be locked, securelg fasten a
prominent warning device, such as a tag, to the service panel.
Remove the filters and locate the blower wire harness connector.
Is it plugged into its mating connector?
If no, plug the blower motor connector into its mating connector on
the top of the hood. Switch the power back on. Check to see if the fan
now works.
If no, check the circuit breaker/fuse. If it is blown/tripped, replace/
reset it. Does the blower work now? If no, call GEfor service.
• Many factors could be the root cause for reduced air-flow.
Installation could be the problem: Your hood was designed to
meet specific ducting requirements. Refer to the Installation
Instructions or if gou do not have them, go to GEAppliances.com.
If gour duct length exceeds the manufacturer's requirements,
hood performance will suffer. Air-flow will also be reduced if the
house duct work is too small or there are too mang elbows in the
sgstem. Contact gour installer or builder.
Obstruction in duct work could be the problem: Hake sure nothing is
blocking the vent (bird nests or kinks in the duct work).
Damper blade mag not be opening. Make sure the tape is removed
from the damper blades and that it swings open freelg.
Damper blade on Wall or Roof Cap may not be opening. Contact
gour builder so theg can make sure the damper swings open freelg.
Dirtg filters/baffles-make
sure filters (and all hood surfaces) are
kept clean of grease and dirt.
Sufficient makeup (replacement} air is required for exhausting
appliances to operate to rating. Check with local building codes,
which mag require or stronglg advise the use of makeup air."
Visit GEAppliances.com for available makeup air solutions.