Installation And Set Up; Connecting Power; Connecting Sl Parblazer 100 Uv To Ac Power - Philips SL ParBlazer 100 UV Installation & User Manual

Table of Contents

Advertisement

SL ParBlazer 100 UV

INSTALLATION AND SET UP

1. Power Requirements
The SL Pa rBlazer 100 UV Luminaire operates on AC input voltages from 100 to 240 VAC.
W ARN ING! The SL ParBlazer 100 UV luminaire does not have an ON/OFF switch. Always disconnect power input cable
to completely remove power from the luminaire when not in use.
AC Power Operation
When connected to an AC source, the unit operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The luminaire
contains an auto-ranging power supply. Each luminaire can draw up to 100 Watts.
W ARN ING! Maximum amount of fixtures that may be daisy-chained is (A) 10 units 100 ~ 120VAC or (B) 23 units
230 ~ 240VAC (15 Amps).
Voltage (AC)
Note: For wiring of AC input connector, refer to

2. Connecting Power

Units can be powered in one of two ways:
Direct connection to an AC power source using an AC input cable. For wiring of the AC input connector, refer to
"Connecting SL ParBlazer 100 UV to AC Power" on page
Connection from the AC output of another SL ParBlaz er 100 UV. When using this method, it is very important not
to connect any other type of equipment device.
W ARN ING! Only connect other SL ParBlazer 100 UV luminaires to the AC Output (Thru) connector of an
SL ParBlazer 100 UV luminaire.
Table 1: SL ParBlazer 100 UVVoltage (VAC) vs. Current*
Total Current (A)
100
1.00
110
0.91
120
0.84
130
0.77
140
0.71
150
0.67
160
0.63
170
0.59
Voltage (AC)
180
190
200
210
220
230
240
"Connecting SL ParBlazer 100 UV to AC Power" on page
6.
Installation & User's Manual
Total Current (A)
0.56
0.53
0.50
0.48
0.45
0.43
0.42
Installation and Set Up