NEC Express5800 120Rj-2 User Manual page 220

Hide thumbs Also See for Express5800 120Rj-2:
Table of Contents

Advertisement

User Guide
On-screen message
Mem Reconfigured
Memory C-Err XX
Memory U-Err XX
PCI Bus PERR XX
PCI Bus SERR XX
Mem Err Disable
Prepare to Boot
On-screen message
240VA Power Down
BB +1.5v Alm XX
BB +1.8v Alm XX
BB +3.3v Alm XX
BB +5.0v Alm XX
BB +1.2v Alm XX
BB P_Vtt Alm XX
BB temp1 Alm XX
DUMP request!
OS Shutdown Alm
Power On Cnt Alm
Power Unit 1 Alm
Figure 187: BIOS Messages (Upper Line)
Description
POST completes with memory
degraded.
A correctable error frequently
occurs in DIMM #XX.
An uncorrectable error has
occurred in DIMM #XX.
A PERR has occurred in the PCI
bus XX.
A SERR has occurred in the PCI
bus XX.
A correctable memory error
frequently occurred.
POST completed normally.
Figure 188: BMC Messages (Lower Line)
Description
Power supply failure occurred.
Voltage alarm occurred on the motherboard.
XX=09: high voltage (fetal)
XX=07: high voltage (warning)
XX=02: low voltage (warning)
XX=00: low voltage (fetal)
motherboard thermal error occurred.
XX=09: high voltage (fetal)
XX=07: high voltage (warning)
XX=02: low voltage (warning)
XX=00: low voltage (fetal)
Dump switch is pressed.
OS Shutdown Alm occurred.
Power Supply Failure occurred.
Power unit #1 Failure occurred.
Action
Contact your service representative.
Try the following steps to cancel the
error.
1. Start BIOS SETUP.
2. Select [Advanced] - [Memory
Configuration] - [Memory Retest] -
[Yes].
3. Select [Exit] - [Exit Saving
Changes].
Contact your service representative.
This is not an error
220