Unit Attention Condition Multiple Hold - Fujitsu MAA3182SC Oem Manual

Intelligent disk drives
Hide thumbs Also See for MAA3182SC:
Table of Contents

Advertisement

(3)
REQUEST SENSE Command
One or the other of the following operations is performed depending on whether or not the
IDD is in the sense data hold state (shown in item 1.6).
a. In the case of a Sense Data Hold State
The IDD executes the REQUEST SENSE command normally and sends the sense data
which are being held to the INIT. In this case, the UNIT ATTENTION condition is not
cleared.
b. In the case of a State other than a Sense Data Hold State
The IDD executes the REQUEST SENSE command normally and sends the sense data
which indicate the UNIT ATTENTION condition and are being held to the INIT. At this
time, the UNIT ATTENTION condition for that INIT is cleared.
1.5.3

UNIT ATTENTION Condition Multiple Hold

If any UNIT ATTENTION condition is generated and a new UNIT ATTENTION condition is
generated for a different reason before the INIT for which the first UNIT ATTENTION
condition was held clears it, those UNIT ATTENTION conditions are held together, and the
IDD reports these multiple UNIT ATTENTION conditions in sequence. For example, a
"Mode parameters changed," "Spindle Synchronized" or "Spindle not Synchronized" or other
UNIT ATTENTION condition may be reported after the "Power on, RESET or BUS DEVICE
RESET occurred" UNIT ATTENTION condition is reported.
1 - 26