Sanyo PDG-DHT100L Service Manual page 44

Multimedia projector
Hide thumbs Also See for PDG-DHT100L:
Table of Contents

Advertisement

Electrical Adjustment
n Wind Sensor calibration
1. Enter the service mode, select group no. "240" and
item no. "0" .
. To start the adjustment, change data value from "0"
to "1". After the auto-calibration completed, "OK" will
appear on the screen.
IMPORTANT
Before taking this adjustment, you need to replace the air
filter with new one or scroll up the filter sheet and make
sure the cabinet top, filter cover and filter cartridge are
securely installed.
-44-