Honeywell Hyperion 1300G User Manual page 82

General purpose handheld linear scanner
Hide thumbs Also See for Hyperion 1300G:
Table of Contents

Advertisement

F1 is the "Send all characters" command
0D is the hex value for a CR
The data is output as: 1234
Stop replacing characters
E5 Terminates character replacement. Syntax = E5.
Compare characters
FE Compare the character in the current cursor position to the character
"xx." If characters are equal, move the cursor forward one position.
Syntax = FExx where xx stands for the comparison character's hex
value for the CP1252 character.
Refer to the
decimal, hex and character codes.
Compare string
B2 Compare the string in the input message to the string "s." If the strings
are equal, move the cursor forward past the end of the string. Syntax
= B2nnnnS where nnnn is the string length (up to 9999), and S consists
of the ASCII hex value of each character in the match string. For
example, B2000454657374 will compare the string at the current
cursor position with the 4 character string "Test."
Refer to the
decimal, hex and character codes.
Check for a number
EC Check to make sure there is an ASCII number at the current cursor
position. The format is aborted if the character is not numeric.
EC Example: Only output the data if the bar code begins with a
number
If you want only data from bar codes that begin with a number, you can
use EC to check for the number.
Command string: ECF10D
EC is the "Check for a number" command
F1 is the "Send all characters" command
0D is the hex value for a CR
If this bar code is read,
if there is one, will be used on the data. If there is no other format, the
format fails and the raw data is output as AB1234.
5 - 12
5678
ABC
<CR>
ASCII Conversion Chart (Code Page
ASCII Conversion Chart (Code Page
1252), page A-3 for
1252), page A-3 for
the next data format,

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents