Honeywell Hyperion 1300G User Manual page 56

General purpose handheld linear scanner
Hide thumbs Also See for Hyperion 1300G:
Table of Contents

Advertisement

42
start character match for Code 128, 42h = "B"
FF
termination string for second code
69
code identifier for Code 93
9999 code length that must match for Code 93, 9999 = all lengths
43
start character match for Code 93, 43h = "C"
FF
termination string for third code
To program the previous example using specific lengths, you would have to
count any programmed prefixes, suffixes, or formatted characters as part of the
length. If you use the example on page 3-11, but assume a <CR> suffix and
specific code lengths, you would use the following command line:
SEQBLK62001241FF6A001342FF69001243FF
The breakdown of the command line is shown below:
SEQBLK sequence editor start command
62
code identifier for Code 39
0012
A - Code 39 sample length (11) plus CR suffix (1) = 12
41
start character match for Code 39, 41h = "A"
FF
termination string for first code
6A
code identifier for Code 128
0013
B - Code 128 sample length (12) plus CR suffix (1) = 13
42
start character match for Code 128, 42h = "B"
FF
termination string for second code
69
code identifier for Code 93
0012
C - Code 93 sample length (11) plus CR suffix (1) = 12
43
start character match for Code 93, 43h = "C"
FF
termination string for third code
3 - 12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents