Patch Data Rewriting When Nonvolatile Memory
was Replaced
On this set, if the nonvolatile memory was replaced, the modified
program data must be written to the nonvolatile memory.
In such a case, write the modified data that meets the microcom-
puter version following the procedure provided below.
• Modified data writing method (version 1.300)
1.
Select the manual mode of the test mode, and set item num-
ber 022 (see page 14).
Remote commander LCD display
022 PatClr CC
2.
Press the X key to initialize the patch data.
(The modified data writing is over, if the adjusted value
changesto DD)
Remote commander LCD display
022 ***SDD
DD : Adjusted value
3.
Press the N key or > key to set item number 023.
Remote commander LCD display
023 Patch00
00 : Adjusted value
[VOLUME +]
4.
Press the
key once to change the adjusted value
to 01.
[DISPLAY]
5.
Press the
key on the remote commander for sev-
eral seconds (about 3 seconds) to activate the patch data write
mode.
(The following display will appear where 00 is blinking)
Remote commander LCD display
023 115800
00 : Adjusted value
[VOLUME +]
6.
Adjust with the
[VOLUME --]
key (adjusted value down) so that the adjusted
value becomes 16.
Remote commander LCD display
023 115816
16 : Adjusted value
7.
Press the X key.
(1158 is blinking)
[VOLUME +]
8.
Press the
key once to change the blinking por-
tion to 1159.
Remote commander LCD display
023 115900
00 : Adjusted value
9.
Press the x /CHG key.
(00 is blinking)
[VOLUME +]
10. Adjust with the
[VOLUME --]
key (adjusted value down) so that the adjusted
value becomes EA.
Remote commander LCD display
023 1159EA
EA : Adjusted value
11. Press the X key.
(EA is blinking)
26
key (adjusted value up) or
key (adjusted value up) or
[VOLUME +]
12. Press the
key three times to change the blink-
ing portion to 115C.
Remote commander LCD display
023 115C00
00 : Adjusted value
13. Press the x /CHG key.
(00 is blinking)
[VOLUME +]
14. Adjust with the
[VOLUME --]
key (adjusted value down) so that the adjusted
value becomes 28.
Remote commander LCD display
023 115C28
28 : Adjusted value
15. Press the X key.
(115C is blinking)
[VOLUME +]
16. Press the
key three times to change the blink-
ing portion to 115F then press the x /CHG key.
Remote commander LCD display
023 115F00
00 : Adjusted value
[VOLUME +]
17. Adjust with the
[VOLUME --]
key (adjusted value down) so that the adjusted
value becomes DE.
Remote commander LCD display
023 115FDE
DE : Adjusted value
18. Press the X key.
(115F is blinking)
[VOLUME +]
19. Press the
key to change the blinking portion to
[DISPLAY]
1178, and press the
for several seconds (about 3 seconds) to exit the patch data
write mode and display as below.
Remote commander LCD display
023 Patch01
01 : Adjusted value
[VOLUME +]
20. Press the
key to display as below.
Remote commander LCD display
023 ****09
09 : Adjusted value
21. Press the [DISPLAY] key on the remote commander for sev-
eral seconds (about 3 seconds) to activate the patch data write
mode. (The following display will appear where 00 is blink-
ing)
Remote commander LCD display
023 117800
00 : Adjusted value
[VOLUME +]
22. Adjust with the
[VOLUME --]
key (adjusted value down) so that the adjusted
value becomes 01.
Remote commander LCD display
023 117801
01 : Adjusted value
23. Press the X key.
(1178 is blinking)
key (adjusted value up) or
key (adjusted value up) or
key on the remote commander
key (adjusted value up) or