Honeywell ADEMCO VISTA-48A Installation And Setup Manual page 35

Hide thumbs Also See for ADEMCO VISTA-48A:
Table of Contents

Advertisement

FIELD
TITLE and DATA ENTRIES
Linked Zone Verification Timer/
*85
Up and About Timer
Linked Zone Timer:
0 = 15 secs
6 = 2-1/2 min #+12 = 8 min
1 = 30 secs
7 = 3 min
2 = 45 secs
8 = 4 min
3 = 60 secs
9 = 5 min
4 = 90 secs
#+10 = 6 min
5 = 2 min
#+11 = 7 min
Up and About Timer: 1-15 hours
Cancel Verify Keypad Display
*86
0 = no "Alarm Canceled" display
1 = yes, display "Alarm Canceled"
Misc. Fault Delay Time
*87
0 = 15 secs
6 = 2-1/2 min #+12 = 8 min
1 = 30 secs
7 = 3 min
2 = 45 secs
8 = 4 min
3 = 60 secs
9 = 5 min
4 = 90 secs
#+10 = 6 min
5 = 2 min
#+11 = 7 min
*88
Exit Options
0 = all intrusion zones must be intact before
arming
1 = All intrusion zones except in exit path
(zone list 12) must be intact before
arming. Will go into alarm if not restored
at end of exit time
2 = All intrusion zones except in exit path
(zone list 12) must be intact before
arming. Will be bypassed if not restored
at end of exit time
3 = Final contact set: All intrusion zones
except in exit path (zone list 12) must
be intact before arming. Once armed,
exit delay remains on indefinitely until
the last zone, as defined in zone list 8,
is restored; then there is 5-second exit
delay before arming state is active
Event Log Full Report Code
*89
0 = disable; 1-F = see description above ∗59
Event Log Enables
*90
0 = no event logging
1 = log Alarm/Alarm Restore
2 = log Trouble/Trouble Restore
4 = log Bypass/Bypass Restore
8 = log Open/Close
x = log combination of events (add value of
entries)
EXPLANATION
Linked Zone Verification Timer:
Sets the maximum amount of time in which two linked zones must
be tripped in an armed system to send an alarm message to the
Central Station. If only one linked zone is tripped during this time, a
trouble message (CID code 380) for that zone is sent to the Central
#+13 = 10 min
Station.
#+14 = 12 min
Assign linked zone pairs in zone list 4.
#+15 = 15 min
Up and About Timer: 1-15 hours. This option is part of an Up and
About schedule (event 12) that must be programmed. The value in
this field is the time within which activity must occur within the
overall scheduled up and about time window. If no zones are faulted
or no key is pressed within the selected time period during the
scheduled Up and About time window, a report is sent to the central
station. This can serve as a safety feature for elderly, infirm, or
disabled persons. See Programming Installer and User
Schedules section for programming schedules.
When enabled (1 = yes), this feature causes an "ALARM CANCELED"
display at the keypad whenever the system is disarmed after an
alarm has occurred.
NOTE: To clear the "ALARM CANCELED" display, the user must
enter the security code + OFF.
Used with zones assigned to a configurable zone type with fault delay
on (selected in alarm/trouble processing prompt), and sets a zone
#+13 = 10 min
response time of 15 seconds to 15 min. It can be assigned to zones
#+14 = 12 min
with sensors that provide a trouble indication when an oil or gas
#+15 = 15 min
tank is low, or similar applications for critical condition monitoring
where a non-alarm response is desired and where the zone response
time should be very long to avoid reacting to normal transient faults.
Select the desired option.
NOTE: Must be "0" if system uses zone type 82 - blockschloss.
If an Event Logging selection is made in field ∗90, a message can be
sent to the central station receiver when the log is 80% full. If the log
becomes full, new messages overwrite the oldest messages in the log.
This system has the ability to record up to 254 events in a history
log. At any time, the downloader operator can then upload the log
and view or print out all or selected categories of the log. The
downloader operator can also clear the log. Event log can also be
viewed at an alpha keypad (see User Guide for log display format).
The display/printout at the central station will show the date, time,
event, and description of the occurrences.
Data Entry Example: To select Alarm/Alarm Restore" and
"Open/Close", enter 9 (1+ 8); to select all events, enter #15.
4-7