Beko DRYPOINT RA 1300-4400 eco Instructions For Installation And Operation Manual page 22

Compressed air refrigeration dryer
Table of Contents

Advertisement

Technical description
Alarm
ID
- High Pressure Switch - Pressure switch HPS has
1
- Low Pressure Switch - Pressure switch LPS has
2
- Fan Protection - Fan electrical protection has
3
- High Discharge Temperature -
Temperature T4 compressor discharge over safety
4
- Compressor Protection - QC1 circuit breaker has
5
Temperature T1 exchanger too low. Condensation
6
7
LP pressure transducer fault
8
HP pressure transducer fault
9
10
- Low Differential Pressure -
Low differential pressure between the values
11
measured by BHP and BLP
- High Evaporating Pressure -
12
- Low Condensing Pressure -
13
1001
Communication fault between the main DMC50 control unit module and the display module
1002
1400
1479
22
Description
triggered
Refrigerant pressure high
triggered
Refrigerant pressure low
triggered
Fan motor overload
limits
tripped
Compressor overload
- ICE -
frozen
- Probe Fault LP -
- Probe Fault HP
- Probe Fault T1 -
T1 temperature probe fault
- Probe Fault T4 -
T4 temperature probe fault
- Power Unit Communication Lost -
Communication fault between the DMC50 control unit and the compressor inverter
Specific compressor inverter alarms
Contact
open
Contact
open
Contact
open
T4>110°C
(230°F)
C. breaker
tripped
T1 < -3°C
(26.6°F)
HP-LP
< 2.5 bar
R134.a 4.5 barg
R407C 7.3 barg
Variable
- Inverter Communication Lost -
Consult the inverter manual
Set
Delay
Flag
immediately
Flag
immediately
Flag
immediately
60
seconds
Flag
immediately
60
seconds
Flag
-
immediately
Flag
-
immediately
Flag
-
immediately
Flag
-
immediately
60
seconds
60...300
seconds
180...300
seconds
DRYPOINT® RA 1300-4400 eco
Reset
Restore
contact
Restore
contact
Restore
contact
T4<100°C
(212°F)
Restore
C.breaker
T1 > 0°C
(32°F)
Restore
transducer
Restore
transducer
Restore
probe
Restore
probe
HP-LP
> 2.5 bar
-
-

Advertisement

Table of Contents
loading

Table of Contents