Honeywell Comfort Window User Manual page 21

Electronic digital thermostat comfort control system

Advertisement

2. Regular System, 2 Heating Units
The second category of wiring configuration
schemes follows a single compressor, dual
heating unit (non-Heat Pump) system, with
either a shared transformer between the
compressor and the first Heating Unit or
separate transformers connected to RC1 and
RH1. In either case, a separate (potentially
third) transformer is needed for RH2.
First, you will need to choose whether your
system has a separate transformer for Heating
Unit #1 than for the Compressor.
outputs include Heating Stage 2, Cooling
Stage 2, Heating Stage 3, and Economizer
Damper Control. Refer to the following charts
while wiring up your system.
Chart 5: Required Wiring for Single
Compressor, Dual Heater Installations
Screw
Terminal
Connect To
Number
1
Jumper to 4
Heater 2 Transformer
2
+24VAC
*Either Jumper to 4
(Shared Transformer)
OR
3
Heater 1 Transformer
+24VAC (Separate
Transformer)
Compressor
4
Transformer
+24VAC
5
Compressor Control
6
Fan Control
7
Heat Control
12
Heater 2 Control
15
-24VAC (Ground)
16
Indoor Temp Probe
17
Indoor Temp Probe
19
Indoor Temp Probe
* *
*Caution! While there are some industry-wide
color-coding conventions, some thermostat makers do
color-coding conventions, some thermostat makers do
not follow these conventions, so it is imperative to record
the previous configuration (both color and function) so
the correct wire can be connected to the appropriate
location on Comfort Window's wall-plate.
Optional
Std.
Function
Wire
Color*
RC2
Red
RH2
Red
RH1
Red
RC1
Red
Y
Yellow
G
Green
W
White
WH2
Dark Purple
Brown/Black
C
**
T1in
Black*
T2in
Yellow*
T3in
Red*
22 of 24
PCB0001C-01-BHP-PDII0614
Chart 6: Optional Wiring for Single
Compressor, Single Dual Installations
Screw
Terminal
Connect To
Number
Heater 1 Stage 2
9
Control
Compressor Stage 2
10
Control
Outside
11
Temp/Humidity Probe
Outside
13
Temp/Humidity Probe
Economizer Damper
14
Control
Outdoor
16
Temp/Humidity Probe
18
Humidifier Output
Outdoor
19
Temp/Humidity Probe
**Note: Brown or Black are the most common
colors for 24VAC ground; however, white and
blue are also frequently used.
Function Proprietary
Wire Color
W2
NA
Y2
NA
OT2in
Yellow
OH1in
Green
ECD
NA
OT1in
Black
HUM
NA
OT3in
Red