Napoleon BGD42NT Manual
Napoleon BGD42NT Manual

Napoleon BGD42NT Manual

Napoleon bgd42nt; bgd42pt gas fireplace

Advertisement

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.22, AND ANSI Z21.50 RESPECTIVELY FOR VENTED GAS FIREPLACES.
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / AGA / CGA METHODS
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapours and liquids in the vicinity of
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
Installation and service must be performed by a qualified installer, service agency or the
Fax: (705)722-6031 Email: ask@napoleon.on.ca
Web: www.napoleonfireplaces.com
DIRECT VENT MILLIVOLT SYSTEM
INSTALLATION AND OPERATION INSTRUCTIONS FOR
DIRECT VENT DECORATIVE GAS FIREPLACE
NATURAL GAS MODEL
PROPANE GAS MODEL

FOR YOUR SAFETY

this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
gas supplier.
Wolf Steel Ltd., 24 Napoleon Rd.,
Barrie, ON., Canada L4M 4Y8 (705)721-1212
R-2000
BGD42NT
BGD42PT
• Immediately call your gas supplier from a
neighbour's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
1
W415-0221 / E / 04.09.02

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon BGD42NT

  • Page 1: For Your Safety

    • If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON., Canada L4M 4Y8 (705)721-1212 Fax: (705)722-6031 Email: ask@napoleon.on.ca R-2000 Web: www.napoleonfireplaces.com...
  • Page 2: Table Of Contents

    TABLE of CONTENTS PG 20 OPTIONAL BLOWER INSTALLATION PG 2-4 INTRODUCTION Warranty OPTIONAL FAN INSTALLATION / General Instructions GD36 THERMOSTATIC SENSOR CON- General Information TROL Care of Glass & Plated Parts 5 - 12 VENTING OPERATION / MAINTENANCE Operating Instructions Venting Lengths Air Terminal Locations Maintenance...
  • Page 3: Warranty

    After the first year, NAPOLEON will not be responsible for installation, labour or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not covered by this warranty.
  • Page 4: General Instructions

    The glass thickness is 3/16". Use only re- bedroom or bathroom unless unit is direct-vent. placement glass available from your Napoleon dealer. DO Mobile home installation must conform with local codes or in the NOT SUBSTITUTE MATERIALS. Clean the glass after the first...
  • Page 5: Venting

    Horizontal runs may have a 0 inch rise per foot in all Wolf Steel and Simpson Dura-Vent venting systems cases using SIMPSON DURA-VENT or NAPOLEON must not be combined. RIGID OR FLEXIBLE venting components when vent- ing as illustrated in Figures 3, and 4.
  • Page 6 Recommended to prevent condensation on windows and thermal breakage ** ** ** ** ** Using a Napoleon soffit heat shield, W585-0096, or equivalent, the distance may be reduced to a minimum of 18". It is recommended to maximize the distance to vinyl clad soffits.
  • Page 7: Typical Vent Installations

    TYPICAL VENT INSTALLATIONS For optimum performance, it is recommended that all horizontal runs have a 1 inch rise per foot. When terminating vertically, the vertical rise FIGURES 3 is a minimum 36 inches and a maximum 40 feet from the centre of the fireplace flue out- let.
  • Page 8 VENTING APPLICATION FLOW CHART vertical termination vertical termination horizontal termination horizontal termination vertical termination vertical termination vertical termination horizontal termination horizontal termination horizontal termination v e r t i c a l v e r t i c a l vertical rise vertical rise vertical rise...
  • Page 9: Elbow Vent Length Values

    DEFINITIONS ELBOW VENT LENGTH VALUES for the following symbols used in the venting calcula- feet inches tions and examples are: 1° 0.03 > - greater than 15° 0.45 > - equal to or greater than 30° 11.0 < - less than 45°...
  • Page 10 TOP EXIT / HORIZONTAL TERMINATION Example 3: when (H ) > (V Simple venting configuration (only one 90° elbow) 90° FIGURE 7 See graph to determine the required ver- 90° tical rise V for the required horizontal run FIGURE 9 = 4 ft = 1.5 ft REQUIRED...
  • Page 11 TOP EXIT - VERTICAL TERMINATION when (H ) < (V Example 4: Simple venting configurations FIGURE 10 90° FIGURE 11 90° 90° 90° See graph to determine the required vertical rise V for the required horizontal run H = 5 ft = 10 ft = 5 + 10 = 15 ft REQUIRED...
  • Page 12 TOP EXIT - VERTICAL TERMINATION Example 5: when (H ) > (V Simple venting configurations = 2 ft = 1 ft = 1.5 ft FIGURE 12 = 2 + 1 + 1.5 = 4.5 ft = 6 ft = 2 ft = 6 + 2 = 8 ft = .03(four 90°...
  • Page 13: Installation

    NOTE: Only a clearance to combustibles of 1" all pitches are available from around the vent pipe is required. your Napoleon dealer. HORIZONTAL INSTALLATION: See Accessories to order the specific kit required. This application occurs when vent- ing through an exterior wall.
  • Page 14: Using Flexible Vent Components

    USING FLEXIBLE VENT COMPONENTS Use only approved aluminum flexible liner kits marked: "Wolf Steel Approved Venting" as identified by the stamp only on the 8” outer liner. 4. Insert the liners through the firestop maintaining the required clearance to combustibles. Holding the air termi- For safe and proper operation of the fireplace, follow nal (lettering in an upright, readable position), secure to the venting instructions exactly.
  • Page 15: Fireplace Vent Connection

    7. If more liner needs to be used to reach the fireplace, 5. Remove nails from the shingles, above and to the couple them together as illustrated. The vent system must be sides of the chimney. Place the flashing over the air termi- supported approximately every 3 feet for both vertical and nal and slide it underneath the sides and upper edge of horizontal runs.
  • Page 16: Restricting Vertical Vents

    VERTICAL VENTING INSTALLATION RESTRICTING VERTICAL VENTS: 1. Move the fireplace into position. Vertical terminations may display a very active flame. As this appearance is not desirable, the vent exit must be 2. Fasten the roof support to the roof using the screws provided.
  • Page 17: Mobile Home Installation

    MOBILE HOME INSTALLATION It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4's and frame to local In Canada, mobile home installation may be vented hori- building codes. FIGURES 31-33. zontally or vertically. In the United States, it may only be It is not necessary to install a hearth extension with this installed vertically.
  • Page 18: Nailing Tab Installation

    NAILING TAB INSTALLATION FIGURES 34a-c 1) Attach the nailing tabs to the corner CORNER posts using the 2 sheet metal screws POST supplied. Secure through the centre of the top and bottom slots in the nailing NAILING tab and then through the existing holes in the corner posts.
  • Page 19: Finishing

    FINISHING DOOR, AND LOUVRE REMOVAL(& IN- STALLATION) FIGURES 36 a-b DOOR OPENING AND CLOSING: The upper lou- GLOWING EMBERS UPPER LOUVRE vres must be removed to al- low the door to be removed. 3. Tear the glowing embers into pieces and place along SLOT Release the four door the front row of ports covering all of the burner area in front of...
  • Page 20: Optional Blower Installation

    OPTIONAL BLOWER INSTALLATION Attach the connectors from the black and white THERMODISC wires to the thermodisc secure thermodisc bracket to the securing stud at the bot- RECEPTACLE / JUNCTION BOX tom left of the unit using a lock washer and wing nut.
  • Page 21: Optional Fan Installation

    GD65 Fan Kit, shown above, which may be or- Unplug the power cord from the receptacle. Connect all dered from your Wolf Steel / Napoleon dealer. wires as shown. With the thermostatic sensor option, the fan, when turned...
  • Page 22: Operation / Maintenance

    10 second total light-up period is satisfactory. If ignition remove the logs to expose both assemblies. takes longer, consult your Napoleon dealer / distributor. 7. Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if necessary.
  • Page 23: Adjustments

    ADJUSTMENTS PILOT BURNER ADJUSTMENT Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a Adjust the pilot screw to provide properly sized flame. Turn more blue flame, but can cause flame lifting from the burner in a clockwise direction to reduce the gas flow.
  • Page 24: Replacements

    3. P UMBER and policies on replacement parts. Normally all parts can be 4. D ESCRIPTION OF PART ordered through your Napoleon dealer or distributor. 5. F INISH When ordering replacement parts always give the following 6. T OP OR REAR VENT information: WARNING: This is a fast acting thermocouple.
  • Page 25: Terminal Kits

    TERMINAL KITS PERISCOPE - GD401 WALL TERMINAL KIT - GD422 ROUND WALL TERMINAL KIT - GD422R ROOF TERMINAL KITS: 1/12 TO 7/12 PITCH GD410 8/12 TO 12/12 PITCH GD411 FLAT ROOF GD412 PART NO. DESCRIPTION W010-0774 AIR TERMINAL W120-0015 VERTICAL CAP W170-0086 STORM COLLAR GZ550-1KT...
  • Page 26: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE EFORE ATTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED SYMPTOM PROBLEM TEST SOLUTION Main burner goes Pilot flame is not large - turn up pilot flame. out;...
  • Page 27 SYMPTOM PROBLEM TEST SOLUTION Pilot goes Gas piping is undersized. - turn on all gas appliances and see if pilot flame flutters, dimin- while standing; ishes or extinguishes, especially when main burner ignites. Monitor Main burner is in appliance supply working pressure. 'OFF' position.
  • Page 28 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage. Service Technician Date Dealer Name Service Performed Special Concerns Name...

This manual is also suitable for:

Bgd42pt

Table of Contents