Note:
. . . . . Parts marked " * " differ according to the model/destination. Refer
to the mount table for each function.
. . . . . The parts marked " # " on schematic diagrams are not mounted.
. . . . . All capacitors are in µF unless otherwise noted. pF: µµF 50WV or
less are not indicated except for electrolytics.
. . . . . All electrolytics are in 50 V unless otherwise specified.
. . . . .
: fusible resistor
. . . . .
: nonflammable resistor
. . . . .
: internal component
. . . . .
: panel designation and adjustment for repair
. . . . . Caution when replacing chip parts
New parts must be attached after removal of the chip.
Be careful not to heat the minus side of a tantalum capacitor,
because it is easily damaged by the heat.
Reference information
RESISTOR
RN
: METAL FILM
RC
: SOLID
FPRD
: NONFLAMMABLE CARBON
FUSE
: NONFLAMMABLE FUSIBLE
RS
: NONFLAMMABLE METAL OXIDE
RB
: NONFLAMMABLE CEMENT
RW
: NONFLAMMABLE WIREWOUND
: ADJUSTMENT RESISTOR
COIL
LF-8L
: MICRO INDUCTOR
CAPACITOR
TA
: TANTALUM
PS
: STYROL
PP
: POLYPROPYLENE
PT
: MYLAR
MPS
: METALIZED POLYESTER
MPP
: METALIZED POLYPROPYLENE
ALB
: BIPOLAR
ALT
: HIGH TEMPERATURE
ALR
: HIGH RIPPLE
VPL-CS5A/CS6/CX6/EX1
Section 6

Diagrams

[Measuring conditions, voltage and waveform]
. . . . . A voltage value is the reference value between the measurement
point and the earth, when the NTSC color bar signal is received
from the color bar generator. (digital multi-meter used: 10 M ohms/
V DC)
. . . . . Unit of voltage is V (volt).
(Voltage variations may occur due to normal production tolerances.)
. . . . .
: B line
. . . . . No mark : NTSC (3.58 MHz) color bar signal.
. . . . .
: Measurement disabled.
. . . . .
: Signal path.
The components identified marked ! are
critical for safety.
Replace only with the part number specified.
Les composants identifiés par la marque !
sont critiques pour la sécurité.
Ne les remplacer que par une pièce portant
le numéro spécifié.