Sony MVE-8000A-C Operation Manual

Dme processor pack multi format dme processor
Hide thumbs Also See for MVE-8000A-C:

Advertisement

DME PROCESSOR PACK
MVE-8000A-C
MULTI FORMAT DME PROCESSOR
MVE-8000A
MKE-8020A
MKE-8021A
OPERATION MANUAL
1st Edition (Revised 1)
MKE-8040A
HK-PSU02
[English]

Advertisement

Table of Contents
loading

Summary of Contents for Sony MVE-8000A-C

  • Page 1 DME PROCESSOR PACK MVE-8000A-C MULTI FORMAT DME PROCESSOR MVE-8000A MKE-8020A MKE-8021A MKE-8040A HK-PSU02 OPERATION MANUAL [English] 1st Edition (Revised 1)
  • Page 2 WARNING: THIS WARNING IS APPLICABLE FOR USA WARNING ONLY. To prevent fire or shock hazard, do not If used in USA, use the UL LISTED power cord specified expose the unit to rain or moisture. below. DO NOT USE ANY OTHER POWER CORD. To avoid electrical shock, do not open the Plug Cap Parallel blade with ground pin...
  • Page 3 For the customers in the USA Für Kunden in Europa (nur MVE-8000A) This equipment has been tested and found to comply with the Dieses Produkt besitzt die CE-Kennzeichnung und erfüllt die limits for a Class A digital device, pursuant to Part 15 of the EMV-Richtlinie (89/336/EWG) sowie die FCC Rules.
  • Page 4 Ce produit est prévu pour être utilisé dans l’environnement électromagnétique suivant: E4 (environnement EMC contrôlé ex. studio de télévision). Periodic inspections To guarantee safe long-term operation, periodic inspections are recommended. Please contact your Sony representative for detailed information about the content and cost of periodic inspections.
  • Page 5: Table Of Contents

    Table of Contents Overview ................6 Features..................6 Overview of the MVE-8000A-C Components ......6 Location and Function of Parts........... 7 Front Panel................7 Rear Panel................. 8 Example System Configuration (MKE-8020A Installed).. 10 MVS-8000/8000A System Configuration ......10 Flow of Video Signals ............11 Example System Configuration (MKE-8021A Installed)..
  • Page 6: Overview

    MVS-8000/8000A system’s center control panel. configured around an MVS-8000/8000A Multi Format Switcher System. The MVE-8000A-C is a generic name of the DME Optional backup power supply processor unit having option boards installed in it. Installation of an optional HK-PSU02 Power Supply Unit...
  • Page 7: Location And Function Of Parts

    Note If a status indicator does not light when you turn a POWER switch on, there may be a fault in the power circuits. Turn the POWER switch off and contact your Sony service representative. Location and Function of Parts...
  • Page 8: Rear Panel

    Rear Panel This figure shows the rear panel when one MKE-8020A is installed in the unit. 1SWITCHER A and B connectors SWITCHER B SWITCHER A AC IN A REMOTE4 REMOTE3 GPI 2 AC IN B REF IN REMOTE2 REMOTE1 DATA CTRL 4GPI and GPI2 connectors...
  • Page 9 * Ethernet is a trademark of XEROX Corporation. For information about Ethernet switches that can be used in an MVS system, contact your Sony service representative. For detailed information about setting up the Ethernet switch, refer to the documentation supplied with the switch.
  • Page 10: Example System Configuration (Mke-8020A Installed)

    HDS-X Series MKS-8010A System Reference video signal Control Unit Reference video signal SWITCHER B SWITCHER A MVE-8000A-C DME Processor Pack Reference video signal BVE-9100 Editing Control System Ethernet switch Ethernet switch Cable with BNC a) It is recommended that the CTRL and b) Terminate with the supplied 75Ω...
  • Page 11: Flow Of Video Signals

    Flow of Video Signals MVE-8000A-C DME Processor Pack SWITCHER B SWITCHER A Reference video signal 100 to 240 V AC power supply DME 1B DME 1A MVS-8400/8300/8200/8000/8000A-C Switcher Processor Pack Monitor MONITOR OUTPUT 1-8 100 to 240 V AC power...
  • Page 12: Example System Configuration (Mke-8021A Installed)

    DCU-2000-C Device Control Unit Pack Reference video signal BKS-R Series HDS-X Series MKS-8010A System Reference Control Unit video signal Reference video signal MVE-8000A-C DME Reference video signal Processor Pack BVE-9100 Editing Control System Ethernet switch Ethernet switch Cable with BNC connectors...
  • Page 13: Flow Of Video Signals

    Flow of Video Signals MVE-8000A-C DME Processor Pack V. K IN V. K OUT REF IN MONI OUT Reference video signal 100 to 240 V AC power supply Monitor Monitor MVS-8400/8300/8200/8000/8000A-C Switcher Processor Pack 100 to 240 V AC power supply...
  • Page 14: Power Supply Unit Status Indicator

    Power Supply Unit Status Indicator The power supply unit status indicator shows the status of the power supply unit during operation and when the unit is powered on. Whenever a power error is detected, it is reflected immediately by the indicator. Meaning of status indicator displays Indicator Status...
  • Page 15: Specifications

    REMOTE 1 to 4 Specifications D-sub 9-pin, female Complies with RS-422A standard Data transfer rate: 38.4 Kbps GPI, GPI2 D-sub 25-pin, female The following specifications show the reference TTL inputs: 8 performance for this unit and individual option boards. Relay contact outputs: 4 (30 V AC/DC, 0.1 A) Design and specifications are subject to change without Open collector outputs: 4...
  • Page 16: Mke-8021A Input/Output Board

    Accessories supplied Dimensions (w/d) 317×380 mm (12 ×15 inches) Operation and Installation Guide (1) Mass Approx. 2 kg (4 lb 6 oz) (supplied only when product is purchased separately) Accessories supplied Operation and Installation Guide (1) MDR 68-pin cables (Part No.:1-823-450-11) (2) (supplied only when product is purchased separately) MDR 68-pin cable...
  • Page 17 The material contained in this manual consists of information that is the property of Sony Corporation and is intended solely for use by the purchasers of the equipment described in this manual. Sony Corporation expressly prohibits the duplication of any...
  • Page 18 Sony Corporation B & P Company MVE-8000A Printed in Japan http://www.sony.net/ (SY) 2004.07.13 3-855-821-02 (1) © 2004 Printed on 100% recycled paper...

This manual is also suitable for:

Mve-8000a

Table of Contents