Water Condensation Drainage

When there is excess water condensation inside the unit, the air conditioner stops running and
shows a warning light (refer to page 10). This warning light indicates that the water condensation
needs to be drained using the following procedures:
Air Conditioning Mode
Water may need to be drained in high humidity areas
1.
Unplug the unit from power source.
2.
Place a shallow pan under the drain plug. See diagram.
3.
Remove the drain plug.
4.
Water will drain out and collect in the shallow pan.
5.
After the water is drained, replace the cap firmly.
6.
You can now turn on the unit.
Dehumidifier Mode
1.
Unplug the unit from power source.
2.
Remove the drain plug.
3.
Connect the drain connector to a ¾" hose(not included). See diagram.
4.
Drain the water condensation into a bucket or a floor drain.
5.
After the water is drained, replace the cap firmly.
6.
You can now turn on the unit.
WATER CONDENSATION DRAINAGE
Drain Plug
(AC Mode)
Shallow Pan
(Not included)
Drain Plug
(De-Humidifier
Mode)