Advertisement

Refurbished Portable Air Conditioner
EN
User Manual
Portable Air Conditioner
Read and save these instructions before use
Refurbished Models Include: "R-"
MM14 Series:
MN09 Series:
MN10 Series:
MN12 Series:
MN13 Series:
MM14CCS, MM14CCSBB, MM14CCSWW, MM14CHCS, MM14CHCSBB, MM14CHCSWW
MN09CES, MN09CESBB, MN09CESWW, MN09CHES, MN09CHESBB, MN09CHESWW
MN10CES, MN10CESBB, MN10CESWW, MN10CHES, MN10CHESBB, MN10CHESWW
MN12CES, MN12CESBB, MN12CESWW, MN12CHES, MN12CHESBB, MN12CHESWW
MN13CES, MN13CESBB, MN13CESWW, MN13CHES, MN13CHESBB, MN13CHESWW
MP09 Series:
MP08 Series:
MF08 Series:
MP09CES, MP09CESBB, MP09CESWW
MP08CES, MP08CESBB, MP08CESWW
MP10 Series:
MP10CES, MP10CESBB, MP10CESWW
Model :
Model :
Model :
Model :
MF08CESBB, MF08CESWW

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell MN09 Series

  • Page 1 Read and save these instructions before use Refurbished Models Include: "R-" Model : Model : Model : Model : MM14 Series: MN09 Series: MP08 Series: MP09 Series: MF08 Series: MM14CCS, MM14CCSBB, MM14CCSWW, MM14CHCS, MM14CHCSBB, MM14CHCSWW MN09CES, MN09CESBB, MN09CESWW, MN09CHES, MN09CHESBB, MN09CHESWW MP08CES, MP08CESBB, MP08CESWW...
  • Page 2 For warranty information, visit: https://www.arcaugusta.com/consumer-warranty.htm USER TIPS Honeywell Portable Air Conditioners are ideal for spot cooling. The compressor, condenser and evaporator are housed in a compact unit. The air is filtered, dehumidified and cooled while a flexible air outlet hose sends heat outside. The air conditioner includes a window venting kit.
  • Page 3: Parts Description

    SAFETY READ AND SAVE THESE INSTRUCTIONS Improper handling can cause serious damage to the appliance. WARNING: • DO NOT operate the unit with a damaged plug or loose wall outlet. If the power cord is damaged, it must be replaced by the manufacturer or an authorized service agent. •...
  • Page 4 INSTALLATION It is important that the installation instructions below are followed for successful installation of this portable air conditioner. Please call Customer Support if you have any difficulties or queries regarding these installation procedures. Installation Kit: Window Bracket Kit......1 Set 1 Piece Window Bracket Panel Adapter...
  • Page 5 INSTALLATION - ALTERNATE KITTING It is important that the installalion instructions below are followed fo, successful installation of tl1is Porlable Air Conditioner Please call Customer Support if you have any difficulties or queries regarding these installation procedures. f () 1. Window Bracket l<it Hole Co•,e, (] Piece) Installation Kit:...
  • Page 6: Use And Operation

    INSTALLATION (CONTINUED) IMPORTANT: • The length of the exhaust hose is determined by the product specifications. Do not replace or lengthen it as this could cause the unit to malfunction. 50 cm / 20” NOT RECOMMENDED RECOMMENDED WARNING: Any warranties included with this product will be voided if an extra extension hose is added to the originally provided installation kit or if the installation is performed differently than the manufactur- er's instructions, without proper consultation.
  • Page 7 USE & OPERATION (CONTINUED) FUNCTION BUTTONS (CONTINUED) POWER CONTROL • Dehumidifying Mode The Power Control turns the unit on and off. When switched on the unit will start on Auto mode. Air is dehumidified as it passes through the unit, without being in full cooling mode. If room tempera- ture is higher than 25°C (77°F) fan speed can be adjusted;...
  • Page 8: Remote Control

    USE & OPERATION (CONTINUED) REMOTE CONTROL The functions work the same as the portable air conditioner's Touch Screen Control Panel. The functions work the same as the portable air conditioner's Control Panel. All key functions can be accessed from the remote control. All key functions can be accessed from the remote control.
  • Page 9: Cleaning And Maintenance

    CLEANING & MAINTENANCE Air filter Air filter Appliance Maintenance: Air filter Turn off the appliance before disconnecting the power supply. Always clean the appliance with a soft dry cloth. Air Filter Maintenance: The air filter should be cleaned every two weeks. Clean it as follows: Turn off the appliance and remove the air filter .
  • Page 10: Water Condensation Drainage

    WATER CONDENSATION DRAINAGE WATER CONDENSATION DRAINAGE When there is excess water condensation inside the unit, the air conditioner stops running and shows a warning light (the Power Control button flashes with a red light). This warning light indicates that the water condensation needs to be drained using the following procedures: Manual Draining for AC &...
  • Page 11: Troubleshooting Guide

    TROUBLESHOOTING GUIDE The following troubleshooting guide addresses the most common problems. If problems persist, call customer service. Unplug and disconnect the appliance from the power source before attempting to troubleshoot. PROBLEM POSSIBLE CAUSE SOLUTION The air conditioning • No electricity. •...