successful (icon on) or not (icon off). On the other hand, the short blinking
of the icon shows that a reception is being done now.
If the signal reception is not successful on the first frequency (915MHz) for
45 seconds, the frequency is changed to 920MHz and the learning is tried
another 45 seconds. If still not successful the reception is tried for 45 seconds
on 910MHz. This will also be done for re-synchronization.

PROGRAM MODE

Programming Note: If 30 seconds is allowed to pass, or the CH button is
pressed during the programming mode, the unit will confirm/set the last
information entered—the display will stop flashing and return to normal
time-date readings. If you don't leave the program mode during the
programming of sections III through XII, you can advance to step 4 of the
next program setting. If you do leave the program setting (or want to
program a specific setting) follow each instructional step to program that
setting.
I.
PROGRAMMING SEQUENCE AND DEFAULT SETTINGS
Please note that while there is a snooze adjustment in the programming this
is an unused function as there is no alarm on the indoor temperature station.
The programming sequence and default (factory) settings are as
follows:
LCD Contrast
Time Zone
Daylight Saving Time
Radio-controlled time reception
12/24-hour time
Time
Year
Day and Month
Snooze (this function not used)
Temperature Format
Setting the forecast sensitivity (this function not used)
2
5
-5 (Eastern)
1 (on)
ON
12
12:00
2006
1.1.
10
°F
7