Things to remember

The temperature at which the unit can be operated is 5¡C to 35¡C.
If the room temperature is over 35¡C, the built-in protection system will automatically turn off the unit.
Dehumidifying operation increases room temperature.
The unit generates heat during operation and will become warm. It will blow out warm air, but this is
normal and does not indicate a problem with the unit.
Dehumidification capacity will vary
based on room temperature and
humidity.
Dehumidification capacity will increase as
temperature rises (as shown in the chart
on the right).
In winter when the room temperature is
low (below 10¡C), use the dehumidifier in
combination with a room heater to reduce
the drying time.
Wait for 3 minutes before restarting the unit
If the unit is turned off, wait for at least 3 minutes before restarting operation.
If the unit is restarted immediately, the compressor will wait for 3 minutes to start up as part of the unitÕs
self-protection system.
Canceling the beeps indicating FULL TANK and
OFF TIMER end
(Operation stopped by AUTO OFF function)
Follow the steps below to disable the tank full alarm:
Plug the power plug into the socket.
When the PLASMACLUSTER and WIDE SWING buttons are pressed
simultaneously during operation stop for at least 3 seconds, the setting
beep sounds.
Press the POWER ON/OFF button and remove the drain tank. If the
beep does not sound, the setting is completed.
To return to the previous condition, either carry out the procedure described
in again or disconnect the power plug from the wall outlet and plug it in
again to cancel the setting.

Defrosting

If the room temperature is below 16¡C, frost may form on the cooling device of the dehumidifier,
and the automatic defrosting function will automatically switch on.
During defrosting, air flow is stopped and the sound of operation will change.
The length of time that defrosting will operate will vary according to room temperature and humidity, but
will be carried out about 5 minutes at 45 minute intervals. (The duration of a defrost cycle will be longer
when the temperature is lower.)
(The dehumidifier does not have a cooling function.)
25
In case of 80%
in humidity.
20
15
10
0
0
15 20 25 30
WIDE SWING button
In case of CONTINUOUS
DEHUMIDIFY operation at
Full power mode.
Room temperature (¡C)
PLASMACLUSTER button
Press together for 3 seconds
E-17