Upper, Lower, And Single Oven High Limits; Oven Sensor (Some Models); Broil Element / Broil Element Reflector; Convection Fan Assembly - Maytag AEW3530DD Series Service Manual

Electric wall ovens
Table of Contents

Advertisement

Disassembly Procedures
!

Upper, Lower, and Single Oven High Limits

NOTE: Requires removal of unit from cabinet.
1. Turn power off to unit.
2. See "Control Panel Assembly" for removal.
3. Remove screws securing top or bottom rear access
cover, to gain access to limits switch.
4. Disconnect wire terminals from limit switch being
replaced.
5. Remove screws securing limit switch needing to be
placed.
6. Replace and reverse procedure to reassemble.

Oven Sensor (some models)

1. Turn off power to unit
2. Open oven door or remove oven door, see "Door
Removal".
3. Remove screws securing sensor to center portion of
broiler element in the rear of the oven cavity.
NOTE: Gently pull wiring through cavity wall.
4. Pull sensor forward, manuver wires through insulation
and broiler element bracket to disconnect wire plug
connector.
5. Replace and reverse procedure to reassemble sensor.
Oven Sensor (some models)
1. Disconnect power before servicing.
2. Open oven door or remove oven door, see "Door
Removal".
3. Remove screws securing sensor to oven cavity.
NOTE: Gently pull wiring through cavity wall.
4. Disconnect oven sensor at the connector block and
remove.
5. Replace and reverse procedure to reassemble sensor.
NOTE: Verify connection is pushed through the
insulation.
©2003 Maytag Appliances Company
WARNING
16022506 Rev. 0
To avoid risk of electrical shock, personal injury or death;
disconnect power to unit before servicing.

Broil Element / Broil Element Reflector

1. Turn off power to unit.
2. Open oven door or remove oven door, see "Door
Removal".
3. Remove screws securing broil element to top and rear
of oven cavity.
4. Allow front of broil element to drop down, then pull
forward to allow terminals to pass through oven cavity.
5. Disconnect wire terminals form element and sensor
wire plug connector.
6. Remove screws securing oven sensor to broil element.
7. Replace and reverse procedure to reassemble broil
element.

Convection Fan Assembly

1. Turn off power to unit.
2. Open oven door or remove oven door, see "Door
Removal".
3. Remove screws securing convection fan cover to
convection fan assembly.
4. Remove screws securing convection fan assembly to
rear of oven cavity.
5. Slide convection fan assembly down and tilt forward on
the top portion to allow assembly to pass through rear
oven cavity.
6. Disconnect and label wires from convection fan motor.
7. Replace and reverse procedure to reassemble
convection fan assembly.
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents