Option 21: Opening Reports; Option 22: Closing Reports; Option 23: Force Armed Report; Option 24: Ac Power Failure Report - GE Simon Installation Instructions Manual

Hide thumbs Also See for Simon:
Table of Contents

Advertisement

Note
For UL listed systems, AC
Power Failure must be set to
15 minutes.
Note
For UL listed systems, CPU
Low Battery Report must be
on.
Simon Security System
¾ To turn off Manual Phone Test, press:
Delete—Option #—20—DONE.
Option 21: Opening Reports (Default = off)
Determines whether the panel sends opening reports to a central station or pager
whenever the system is disarmed (on), or not (off).
¾ To turn on Opening Reports, press:
Add—Option #—21—DONE.
¾ To turn off Opening Reports, press:
Delete—Option #—21—DONE.
Option 22: Closing Reports (Default = off)
Determines whether the panel sends closing reports to a central station or pager when-
ever the system is armed (on), or not (off).
¾ To turn on Closing Reports, press:
Add—Option #—22—DONE.
¾ To turn off Closing Reports, press:
Delete—Option #—22—DONE.
Option 23: Force Armed Report (Default = off)
Determines whether the panel sends a force armed report to a central station or pager if
the user bypasses protesting sensors (indirect bypass) when arming the system (on), or
not (off).
¾ To turn on Force Armed Report, press:
Add—Option #—23—DONE.
¾ To turn off Force Armed Report, press:
Delete—Option #—23—DONE.
Option 24: AC Power Failure Report (Default = off)
Determines whether the panel sends AC power failure reports to a central station or
pager after the programmed time expires (on), or not (off).
When the panel is without AC power for 30 seconds, the panel LEDs turn off. When
the panel is without AC power for the programmed time, an AC power failure is
reported. The panel reports an AC power restoral when AC power returns to the panel.
The time can be set from 5-254 minutes. Entries must be 3 digits.
¾ To turn on AC Power Failure Report, press:
Add—Option #—24—005 - 254—DONE.
¾ To turn off AC Power Failure Report, press:
Delete—Option #—24—DONE.
Option 25: CPU Low Battery Report (Default = on)
Determines whether the panel sends a low CPU battery report to the central station
when the panel backup battery voltage drops below 5.4 volts (on), or not (off).
¾ To turn on CPU Low Battery Report, press:
Add—Option #—25—DONE.
¾ To turn off CPU Low Battery Report, press:
26