Simon XTi Installation Guide
Content
Contact information ................................................................................ 1
Description ................................................................................................... 1
Installation.................................................................................................... 1
Connecting hardwired devices........................................................... 2
Wiring phone lines.................................................................................... 3
Wiring the power transformer ............................................................ 4
Resetting memory to factory defaults ............................................ 4
Programming.............................................................................................. 4
Status & Settings screen........................................................................ 5
Sensors ......................................................................................................... 7
Cleaning the touch screen.................................................................... 9
Disposal ......................................................................................................... 9
Specifications........................................................................................... 10
Regulatory information ....................................................................... 10

Contact information

www.utcfireandsecurity.com
For customer support, see
www.interlogix.com/customer-support
GE and the GE monogram are trademarks of the General Electric
Company and are under license to UTC Fire & Security, 9 Farm
Springs Road, Farmington, CT 06034-4065
Copyright © 2012 UTC Fire & Security. All rights reserved.

Description

This is the Installation Guide for the Simon XTi system (models 600-
1054-95R-12 and 600-1054-95R-12-CN).
Table 1: Sensors and recommended sensor groups
Device
Part number
Indoor motion sensor
60-639-95R, 60-807-95
Entry/exit door
60-362N-10-319.5
Interior door
60-362N-10-319.5
Door/Window sensor
60-362N-10-319.5
Smoke sensor
TX-6010-01-1
Glassbreak sensor
60-873-95
or
www.interlogix.com
Recommended
sensor group
15, 17, 18, 20, 28, or
b
32
10
14
13
26
c
13
b
Device
Part number
4-Button Key fob
600-1064-95R
Simon XT Talking Touch
60-924-3-XT-2WTTS
Screen
60-924-RF-TS
Simon XT Talking
60-924-3-XT
Touchpad
Carbon Monoxide alarm
TX-6310-01-1
6520-95
a.
Not certified as a primary protection circuit for UL-listed systems
and is for supplementary use only.
b.
Has not been investigated by UL.
c.
Required for UL-listed residential fire alarm applications.
d.
The TWTTS has been verified for use by ETL. Neither this device
nor other devices that employ the UTCFS 80 Bit Enhanced
Protocol have been investigated for use by UL.
Note: These sensor groups are only recommendations. The installer should
choose the correct sensor group for the application.
Caution:
Do not use outdoor motion sensors for intrusion
protection.

Installation

Panel location
Locate the panel where alarm sounds can be heard and where
the panel will be easily accessible for operation. Do not install the
panel near a window or door where it can be reached easily by an
intruder.
Recommended
sensor group
01
b
00, 01, 04, 05, 06, or
b
07
d
01
b
, 600-
34
b
b
P/N 466-2449 • REV A • 21FEB12

Advertisement

Table of Contents
loading

Summary of Contents for GE 600-1064-95R b

  • Page 1: Table Of Contents

    For customer support, see www.interlogix.com/customer-support GE and the GE monogram are trademarks of the General Electric Installation Company and are under license to UTC Fire & Security, 9 Farm Springs Road, Farmington, CT 06034-4065 Panel location Copyright © 2012 UTC Fire & Security. All rights reserved.
  • Page 2: Connecting Hardwired Devices

    Figure 2: Mounting holes Mounting Mounting hole Figure 1: XTi chassis and trim ring Wiring knockout Mounting hole Secure the mounting screws (provided) to the locations on the wall marked in step 6. Do not tighten the screws. Leave enough clearance to mount the mounting plate. Note: Use wall anchors if no studs are present.
  • Page 3: Wiring Phone Lines

    Interior sirens Wiring phone lines From the factory, the HW1 I/O input (terminal 1) is set up for You can connect a phone line to the panel for systems monitored interior siren operation (status and alarm sounds). The HW1&2 DC by a central monitoring station or systems that notify users by a out (terminal 2) provides the positive (+) voltage.
  • Page 4: Wiring The Power Transformer

    contact you if they want to add a phone or other device so that Applying AC power you can rewire for full line seizure by adding an RJ31X. Make sure the outlet is not controlled by a switch or that it is not part of a ground fault circuit interrupt (GFCI).
  • Page 5: Status & Settings Screen

    Status & Settings screen Item Description Speaker Provides voice output and sounds key beeps. The Entering and exiting the Status & Settings screen panel speaks arming level change, system status, and voice chime sensor trips. The panel voice is also To enter the Status &...
  • Page 6 Option How to view Option How to view Default Screen Use this feature to set this panel’s screen saver Press the Timers icon to access the following timers mode. Select “Blank” to have the screen and LED go options: dark after a period of inactivity. Otherwise, the •...
  • Page 7: Sensors

    Press Enter. Sensors Enter the dealer or installer code (see Table 4 below) and These instructions describe how to add (learn) sensors, touchpads, press OK. and other system devices into panel memory. The panel recognizes a sensor when you press a sensor program icon, press Note: You have four seconds between number presses to and release a tamper switch, press a sensor test button, or put a enter the code or you will be returned to the home screen.
  • Page 8 Note: While the sensor test is a valuable installation and service Device To program tool, it only tests sensor operation for the current conditions. You Simon XT talking Press the Lights off button on the touchpad six times in should perform a sensor test after any change in environment, touchpad rapid succession.
  • Page 9: Cleaning The Touch Screen

    • Conduct sensor test whenever changes are made to the Sensor Instructions Minimum packets required installation environment that may impact RF performance (For example: mirrors installed, metal backed wall paper, Simon XT talking For sensor testing a 1.0. touch 6 of 8 touch screen screen, press and hold the addition of other RF equipment).
  • Page 10: Specifications

    Specifications Household fire warning system (UL 985), basic system plus the following: Power 9 VAC, 60 Hz, 25 VA transformer minimum • Wireless smoke sensor 60-848-02-95, TX-6010-01-1 learned Rechargeable battery: 6.0 VDC, 2.1 Ah NIMH. into sensor group 26. Maximum battery charging current is 120 mA. •...
  • Page 11 Residential burglary alarm system unit (ORD-C1023-1974): basic Function Default setting Required setting system as described for UL 1023 listed installations plus: Duress/panic code Disabled Disabled • Hardwired magnetic contact (1038T) or wireless learn mode Cross zone Disabled Disabled for zones with high probability of false door/window sensor (60-670) alarms...