Supported Raid Controllers And Required Cables - Cisco UCS C240 M4 Installation And Service Manual

Hide thumbs Also See for UCS C240 M4:
Table of Contents

Advertisement

Supported RAID Controllers and Required Cables

Supported RAID Controllers and Required Cables

This server supports the RAID controller options, cable requirements, and RAID backup units shown in
Table
Caution
Do not mix controller types in the server. Do not use the embedded MegaRAID controller and a hardware
RAID controller card at the same time. This combination is not supported and could result in data loss.
Note
The embedded RAID option is available only with the SFF 8-drive, direct-connect backplane. It does not
operate through an expander.
Table C-1
Cisco UCS C240 M4 RAID Options
Controller
Style
1
Embedded RAID
Onboard
(PCH SATA)
Cisco UCS 12G SAS
PCIe
Modular RAID
Controller
This controller can be
ordered with modular
flash-based write
cache (FBWC)
options: 512 MB,
1 GB, 2 GB, or 4 GB.
Cisco UCS RAID SAS
PCIe
9300-8E HBA
1. The embedded RAID controller is supported only with the SFF 8-drive backplane version of the server (see
2. Embedded RAID 5 support requires an optional RAID 5 key module.
3. SCPM = SuperCap power module (RAID backup unit). See
Cisco UCS C240 M4 Server Installation and Service Guide
C-2
C-1.
Server Version/
Maximum Drives Controlled
SFF 8-drives/no expander:
8 internal SATA drives
SFF 8-drives/no expander:
8 internal drives
SFF 16-drives/expander:
16 internal drives
SFF 24-drives/expander:
24 internal drives
LFF 12-drives/expander:
12 internal drives
All server versions
8 external SAS+SATA
ports, controlling up to 1024
non-RAID external drives
RAID Backup Units, page
Appendix C
SCPM
RAID Levels Required Cables
2
No
0, 1, 5
, 10
3
Yes
0, 1, 5, 6,
10, 50, 60
No
Non-RAID
Embedded SATA RAID Controller, page
C-3.
RAID Controller Considerations
SFF 8-drives/no expander:
Cable and required SATA
interposer board bundled as
UCSC-IP-PCH-C240M4=
SFF 8-drives/no expander:
(
)
UCSC-CBLMR8=
SFF 16 drives/expander:
(
)
UCSC-CBLMR16=
SFF 24 drives/expander:
(
)
UCSC-CBLMR24=
LFF 12 drives/expander:
(
)
UCSC-CBLMR12=
External drive cables are not
sold by Cisco.
C-8).
OL-32474-01