Mounting standard metal fixtures (PDA-4001 • PDA-4002)
4.10 Infrared reduction filter: PDA-4001
Protective filter: PDA-4002

4.10.1 Specifications and features (Infrared reduction filter: PDA-4001)

1) Specifications
Transmittance .................... Transmittance of light in the visible spectrum - 70%
Outer dimensions .............. 908 (W) × 73.3 (D) × 908 (H) mm
Weight ................................ 3.6 kg (filter only)
Material .............................. Acrylic
Packing dimensions .......... 1115 (W) × 815 (D) × 76 (H) mm
Packing weight .................. 7.6 kg
Accessories
Metal fixture ........................................................... 4 pcs
Hexagonal socket button head bolt (M8 x18) ........ 8 pcs
Washer ................................................................... 8 pcs
Decorative screw ................................................... 4 pcs
Filter ....................................................................... 1 pc
2) Features
Mounting the infrared reduction filter (PDA-4001) reduces emission of very weak infrared radiation produced by the
plasma display. In addition, its effect is verified using the equipment described below.
7 Pioneer's audio and visual equipment
¶ If the filter is not mounted:
Use of Pioneer AV equipment near the display when the filter is mounted may interfere with remote control
operation function.
¶ If the filter is mounted:
Check function under the following conditions:
The light-accepting section positioned opposite the PDP screen, and operation verified at a distance of 1 m or
greater from AV equipment.
7 Pioneer's infrared microphone
¶ If the filter is not mounted:
Noise may result, and normal operations may not be possible.
¶ If the filter is mounted:
Check function under the following conditions:
Verification at a distance of 2 m or greater from the front of the display.
Mice level: Hi
When a satellite is used, it is positioned at a distance of 2 m or greater from the front of the display.
7 Optic LAN
¶ If the filter is not mounted:
Normal operations may not be possible.
¶ If the filter is mounted:
Check function under the following conditions:
Operation at a distance of 2 m or greater from the front of the display.
90
<Ver. 2.1>
34.4 kg <35.2 kg> (metal fixture with plasma display PDP-V401 <PDP-V401E>)
2 m