12) The following transmission progress will be shown on the PC.
13) The following receipt will be issued when all the data has been received.
(ECR will be terminated automatically if data is not receiving 5 second or more)
R A C
9 1 4
R A C
I P L
O K
E N D
9 1 4
This process will take approximately 20 minutes to send IPL data to the RAC-12B.
* Please keep the special RAC memory pack for IPL, otherwise you need to do the above process again.
3-2. Send the IPL data from RAC to ECR.
1) Pull out AC cord from wall outlet.
2) Insert the RAC-12B which has the IPL data to the ECR.
3) Press and hold "Journal" feed key and plug in AC cord to the wall outlet.
4) Wait few second and release Journal feed key.
"BT-INIT" should be displayed on the ECR.
5) Enter 44449999 and press "Sub Total" key, then enter 30 and press "Sub Total" key.
6) Back light will be turned off and start loading IPL data from RAC.
7) When the loading is completed, "INIT 0000000000" will be displayed.
8) Enter 99990000 and press "Sub Total" key, then "DIAG 1" will be displayed.
9) Enter your locale code and press "Sub Total" key, then locale code will be printed.
* Locale code is as follows;
Europe: No need to enter the locale code. Skip 8) - 11), go to 12).
U.S.A. and Canada: 200016
Others: 600016
10) Turn the MODE KEY is "OFF". Then while holding down the "JFEED" button, turn MODE KEY to "PGM".
11) Release "JFEED" button, then "INIT 0000000000" will be displayed.
12) Enter your INIT code and press "Sub Total" key, then the information will be printed.
* INIT code is as follows;
Model Name
SE-C300 / SE-C2000
SE-S2000
SE-S300
TE-1500
TE-900
TK-950 / TK-1550
PCR-T2100 / PCR-T2200 / PCR-T220S
PCR-T2100L / PCR-T2200L
PCR-T470 / PCR-T480 / PCR-T48S
PCR-T470L / PCR-T480L
INIT Code
17200
13040
12540
23040
22540
27200
23000
93000
22500
92500
— 8 —