Honeywell Xenon 1902 Quick Start Manual

Honeywell Xenon 1902 Quick Start Manual

Cordless area-imaging scanner
Hide thumbs Also See for Xenon 1902:

Advertisement

QUESTIONS?
Ask the experts at POSMicro.com.
1.800.241.6264
Live Chat Now
support@POSMicro.com
Monday - Friday 6 AM to 5 PM Pacific Time
1.800.241.6264
Honeywell Quick Start
Guide - Xenon 1902
THIS DOWNLOAD APPLIES TO THE FOLLOWING
Xenon 1902
Xenon 1902 Color
BULk DISCOUNTS
FREE SHIPPING*
*Free ground shipping to the continental USa on orders over $100.
For Help Call
SE HaBLa
ESpañOL

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Xenon 1902

  • Page 1 For Help Call 1.800.241.6264 Honeywell Quick Start Guide - Xenon 1902 THIS DOWNLOAD APPLIES TO THE FOLLOWING Xenon 1902 Xenon 1902 Color QUESTIONS? BULk DISCOUNTS SE HaBLa Ask the experts at POSMicro.com. ESpañOL FREE SHIPPING* 1.800.241.6264 Live Chat Now support@POSMicro.com Monday - Friday 6 AM to 5 PM Pacific Time *Free ground shipping to the continental USa on orders over $100.
  • Page 2: Quick Start Guide

    Xenon™ 1902 Cordless Area-Imaging Scanner Quick Start Guide Aller à www.honeywellaidc.com pour le français. Vai a www.honeywellaidc.com per l'italiano. Für Deutsch gehe zu www.honeywellaidc.com. Ir a www.honeywellaidc.com para español. Para Português, acesse www.honeywellaidc.com.br. Перейти на русскоязычный сайт www.honeywellaidc.com. 日本語 : をご覧ください。...
  • Page 3: Getting Started

    Note: Refer to your user’s guide for information about cleaning your device. For localized language versions of this document, go to www.honeywellaidc.com. Getting Started Turn off the computer’s power before connecting the base, then power up the computer once the base is fully connected. When the base is connected and powered up, put the scanner in the base to establish a link.
  • Page 4 Connecting the Scanner USB: Keyboard Wedge:...
  • Page 5 RS232 Serial Port: RS485:...
  • Page 6: Reading Techniques

    Reading Techniques The view finder projects an aiming beam that should be centered over the bar code, but it can be positioned in any direction for a good read. Hold the scanner over the bar code, pull the trigger, and center the aiming beam on the bar code.
  • Page 7: Keyboard Country

    RS485 Interface The RS485 interface defaults to port 5B. If you have an IBM POS terminal using port 9B, scan the appropriate code below to program the terminal, then power cycle the cash register. IBM Port 9B HHBCR-1 Interface IBM Port 9B HHBCR-2 Interface Note: For additional RS485 interface selections, see the User’s Guide for your product at our website,...
  • Page 8 Country Code Scan Country Code Scan Finland Spain France Switzerland Germany/Austria USA (Default) Great Britain Save Note: For a complete list of country codes, see the User’s Guide for your product at our website, www.honeywellaidc.com. Locked Link If you link a scanner to a base using the Locked Link Mode, other scanners are blocked from being linked if they are inadvertently placed into the base.
  • Page 9: Override Locked Scanner

    Override Locked Scanner If you need to replace a broken or lost scanner that is linked to a base, scan the Override Locked Scanner bar code with a new scanner, and place that scanner in the base. The locked link will be overridden;...
  • Page 10 Trigger The following bar codes will allow you to use the scanner in Manual Trigger - Normal Mode (need to press the trigger to read) or Presentation mode (the scanner is activated when it “sees” a bar code). Manual Trigger - Normal (Default) Presentation Mode Streaming Presentation™...
  • Page 11: Add Code Id Prefix To All Symbologies

    Suffix If you want a carriage return after the bar code, scan the Add CR Suffix bar code. To add a tab after the bar code, scan the Add Tab Suffix bar code. Otherwise, scan the Remove Suffix bar code to remove the suffixes.
  • Page 12: Function Code Transmit

    Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in your User’s Guide. When the scanner is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted.
  • Page 13: Data Format Editor Instructions

    Data Format Editor Instructions The following are abbreviated instructions for entering a data format. For complete instructions refer to your User’s Guide, available at our website, www.honeywellaidc.com. 1. Scan the Enter Data Format symbol. 2. Primary/Alternate Format: scan 0 for Primary Format 3.
  • Page 14: Programming Chart

    Programming Chart...
  • Page 15 Save...
  • Page 16: Technical Assistance

    For localized versions of this document, and to download the User’s Guide, go to www.honeywellaidc.com. Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made.
  • Page 17 Other product names or marks mentioned in this document may be trademarks or registered trademarks of other companies and are the property of their respective owners. Web Address: www.honeywellaidc.com...

This manual is also suitable for:

Xenon 1902 color

Table of Contents