High Temperature Shut Off System; Not Enough Hot Water; Water Is Too Hot - Kenmore POWER MISER 153.336151 Owner's Manual

Kenmore water heater user manual
Table of Contents

Advertisement

Troubleshooting
Guide (cont'd)
Operational
Conditions
(cont'd)
HIGH
TEMPERATURE
SHUT
OFF SYSTEM
This waterheater is equipped with an automatic gas shut off sys-
tem. The high temperature shut off is built into the gas control
valve. This system shuts off the gas supply to the water heater
burners when high water temperatures are present. It is non-
resettable. I f the high temperature shut offactivates, the gas con-
trol valve must be replaced. If this were to occur,turn _OFF_'the
entire gas supply to the water heater. Contact the Sears Service
Center.
AWARNING
Shouldoverheating occuror the gassupply fail to shut off,
tom "OFF" the manualgascontrolvalveto the appliance,
&WARNING
Due to the nature of the typical gas water heater, the
water temperature
in certain situations
may be hotter
than the thermostat
setting.
Short, frequent draws of hot water - especially with very
cold incoming water - can shock the thermostat
into brief
operation resulting in hotter and hotter layers of water
closer to the top of the tank.
Changes in hot water usage patterns or raising the tem-
perature differential between the cut-on of the thermo-
stat and the cold water temperature will usually eliminate
the problerr_
NOT ENOUGH
OR NO HOT WATER
i
heck the manualgasshut offvalve to be sure it is open.
Check the pilot flame. It mayhave gone out. All models have
an openingbehindthe outerdoor f_r viewingthe pilot.
If the pilot is not lit, f_llow the _Lighting"instructions in this
manual or located above the gas control valve on the water
heater to relight the pilot. If the water was extremdy hot and
is now cold, the high limit safety temperature shut off may
have put out the burner and pilot. If the high temperature
shut off activates, the gas control valve must be replaced.
Contact the SearsServiceCenter.
u
n
.
,
• The gas control knob must be turned m the
ON
posmon.
• The temperature
adjustment
dial may be set too low. See the
"Tempetature
Regulation"
section.
The gas company
can check the gas input to see if it is correct.
An underfired
water heater will not heat water as quickly.
Look for leaking or open hot water
faucets.
Make sure all are
dosed.
• The cold water inlet temperature may be colder during the
winter months. It will take[onget to heat the water and seem
like lesshot water.
• If you cannot find what is wrong, call the Scars Service
Center.
WATER
IS TOO
HOT
1. The temperature adjustment dial may be set too high. So: the
t j tment ° ion.
NOTE: A period of time is necessaryafter an adjwtme_t has
been made for the water temperanLee to reach the new tem-
penturesetting.
2. If lowertemperature settingswill not lower the watertempera-
ture, call the SearsServiceCenter.
24

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents