Service And Maintenance; Venting System Inspection; Burner Inspection - Maytag HN41240X User Manual

Series twelve gas water heater
Table of Contents

Advertisement

Service and Maintenance
Venting
System
Inspection
Burner
Inspection
At least once a year a visual inspection should be made of the
[
_WARNING
venting system.You should look for:
_| F lood damage to a_may
not be readily
• Obstructions which could cause improper venting. The
| visible or immediately
detectible.
However, over a
combustion and ventilation air flow must not be obstructed.
"period of time a flooded
water
heater will create
dangerous conditions which can cause DEATH, SERI-
OUS BODILY INJURY
OR PROPERTY
DAMAGE.
• Damage or deterioration which could causeimproper vent-
Contact the Maytag
dealer from whom the appli-
ing or leakage of combustion products,
ance was purchased or call Maytag Customer Service
at 1-800-788-8899
for an authorized
servicer
to
replace a flooded water heater. Do not attempt to
• Rusted flakes around top of water heater,
repair the unit! It must be replaced!
At least once a year a visual inspection should be made of the
AWARNING
main burner and pilot burner. The drawing is for your reference.
Chemical vapor corrosion of the flue and vent sys-
tem may occur if air for combustion contains certain
You should check for sooting which is not normal and will
chemical vapors. Spray can propellants, cleaning sol-
vents, refrigerator
and air conditioner refrigerants,
impair proper combustion.
swimming pool chemicals, calcium and sodium chlo-
ride, waxes, bleach, and process chemicals are typi-
[ca compounds wh ch are potent a y corros ve.
Obstructed or deteriorated
vent systems may pres-
ent a serious health risk or asphyxiation.
NATURAL GAS BURNER - 40 AND 50 GALLON
I
]
Be sure the vent
_erly
connected to I
_)_
prevent
escape of dangerous
flue gasses which
could cause deadly asphyxiation.
AWARNING
If after
inspection of the vent system you found
PROPANE ( L.R)GAS BURNER-40AND 50GALLON
sooting or deterioration,
something
is wrong. Call
the local gas utility or Maytag Customer Service at
1-800-788-8899 for an authorized servicer to correct
the problem and clean or replace the flue and vent-
ing before resuming operation of the water heater.
Failure to make corrections can result in a fire, or
explosion causing DEATH, SERIOUS BODILY INJURY,
OR PROPERTY DAMAGE.
NATURAL AND PROPANE (L.R) GAS BURNER - 75 GALLON
AWARNING
Soot build-up indicates a problem that requires cor-
rection before further use. Turn "OFF" gas to water
heater
and leave "OFF"
until repairs are made,
because failure to correct the cause of the sooting
can result in a fire or explosion
causing DEATH,
SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.
22