High Voltage Fuse; Transformer; Filter Assembly / Fuse; Blower Assembly - Maytag ALD510D Service Manual

2006 international countertop commercial microwave ovens
Table of Contents

Advertisement

Disassembly Procedures
!
WARNING

High Voltage Fuse

1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Discharge high voltage capacitor, (see "High Voltage
Capacitor" section).
3. Disconnect high voltage fuse wire terminals from
transformer and capacitor.
4. Replace high voltage fuse and reverse procedure to
reassemble.

Transformer

1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Discharge high voltage capacitor, (see "High Voltage
Capacitor" section).
3. Disconnect and label wire leads from transformer.
4. Place unit on it's back to gain access to mounting
screws.
5. Remove screws securing transformer and remove.
6. Replace transformer and reverse procedure to
reassemble.

Filter Assembly / Fuse

1. Disconnect power to oven and remove outer case,
(see "Outer Case" section).
2. Remove fuse from filter assembly board. See caution
below.
3. Disconnect and label wires from filter assembly.
4. Remove screw securing ground wire to chassis.
5. Carefully press tabs to release assembly from
locating pin.
6. Replace component(s) and reverse procedure to
reassemble.
!
CAUTION
Before replacing a blown monitor fuse, test the primary
interlock switch, secondary interlock switch, monitor
switch, and power relay contacts for proper operation.
If the monitor fuse is blown by a failed switch
operation, all switches and controller must be
replaced.
©2006 Maytag Services
To avoid the risk of electrical shock, personal injury, or death,
disconnect power to oven and discharge the capacitors before
following any disassembly procedure.

Blower Assembly

1. Disconnect power to oven.
2. Remove outer case, see "Outer Case" procedure.
3. Disconnect wire terminals from blower motor.
4. Remove noise filter board from blower assembly
bracket.
5. Remove screws securing vent deflector located on the
rear of the unit.
6. Press downward on upper plastic tab securing blower
assembly to rear chassis wall.
7. Tilt top portion of blower assembly inward and raise
upward to release bottom securing tabs.
8. Replace component and reverse procedure to
reassemble.
Noise
Filter
Blower
Motor
Assembly
16026969
Fuse