T7200D,E, T7300D,E,F AND Q7300 SERIES 2000 PROGRAMMABLE COMMERCIAL THERMOSTATS AND SUBBASES
IMPORTANT
Review the settings to confirm that they match the
system. Press Run Program to exit the Installer
Setup. The thermostat has saved the Installer Setup
changes and initiated reset in order to operate with
these new settings. Be sure to set the current day
and time immediately.
Setting Current Time/Day
1. Press Set Current Day/Time.
NOTE: On initial power up or after an extended
power loss, 1:00 pm flashes on the display
until a key is pressed.
Set Current
Set Program
Set Temperature
Day/Time
Run
Occupied
Unoccupied
Occupied
Unoccupied
Program
Start Time
Start Time
Day
Temp
Temporary
Set Current
Clear
Heat/Cool
Occupied
Day/Time
Start Time
Copy
Settings
Continous
Unoccupied
System
2. Press Day until the current day is displayed.
NOTE: Sun = Sunday, Mon = Monday, Tue = Tuesday,
Wed = Wednesday, Thu = Thursday, Fri =
Friday, Sat = Saturday.
Day
Set Program
Set Temperature
Change
Time/Temp
Run
Occupied
Unoccupied
Occupied
Unoccupied
Program
Start Time
Start Time
Day
Temp
Temp
Temporary
Set Current
Clear
Heat/Cool
Occupied
Day/Time
Start Time
Copy
Settings
Continous
Unoccupied
System
Fan
3. Press increase
or decrease
time is displayed.
NOTE: Tapping the Set Current Day/Time will change
the time in one hour increments.
Set Program
Set Temperature
Change
Time/Temp
Run
Occupied
Unoccupied
Occupied
Unoccupied
Program
Start Time
Start Time
Day
Temp
Temp
Temporary
Set Current
Clear
Heat/Cool
Occupied
Day/Time
Start Time
Copy
Settings
Continous
Unoccupied
System
Fan
4. Press Run Program.
Run
Program
Set Program
Set Temperature
Time/Temp
Run
Occupied
Unoccupied
Occupied
Unoccupied
Program
Start Time
Start Time
Day
Temp
Temp
Temporary
Set Current
Clear
Heat/Cool
Occupied
Day/Time
Start Time
Copy
Settings
Continous
Unoccupied
System
Fan

INSTALLER SYSTEM TEST

Use the Installer System Test to check the thermostat
configurations and operation. Refer to Table 9 for a list of the
available system tests.
63-4355—1
Set Day/Time
PM
Change
Time/Temp
Temp
Mon
Fan
M4951B
Set Day/Time
PM
Tue
M4952B
key until the current
Set Day/Time
PM
Tue
M4953B
AM
Room
Change
Mon
Occupied 1
System
Fan
Heat
Auto
M4954A
To start the system test:
CAUTION
The minimum off time for compressors is bypassed
during the Installer System Test. Equipment damage
can occur if the compressor is cycled too quickly.
Press and hold the increase
same time, until 10 appears. All segments of the LCD are
displayed for three seconds before 10 appears. See Fig. 14
and 15.
Set Program
Start Time
Em Ht
Aux Ht
Comm
Mon
TueWedThuFriSatSun
Un
Occupied 12 Override
System
Em Heat
Off
Cool
Auto
Fig. 14. Display of all the segments of the LCD.
TEST NUMBER
Fig. 15. Display of test number.
Table 9. Tests Available in Installer System Test.
Test
Number
System Test Description
10 to 19
Heating equipment can be turned on and off
20 to 29
Emergency heat (Q7300C,D only) equipment
can be turned on and off
30 to 39
Cooling equipment can be turned on and off
40 to 49
Fan equipment can be turned on and off
60 0 to
Keyboard keys test
60 19
70 to 79
Thermostat information including date code
and software versions are displayed
NOTE: If a duct temperature sensor is installed (T7300F
only), the duct temperature will also be displayed.
Refer to Table 10 and Thermostat Information section for
directions and results of the specific system tests.
NOTE: Press Run Program to exit the system test. The
system test times out after four minutes without any
key presses.
14
and
decrease keys, at the
Temporary Setting Enrg
Set Day/Time
Sav
AM
Room
PM
%Humid
Heat
Cool
Remote
In
Recovery
Auto
Only
Duct
Lo
Med
Hi
Fan
Wait
On
Auto
M10257A
M4916

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents