Dialer Programming ( ∗ 40 - ∗ 50); Pabx Access Code - Honeywell Ademco Vista-12D Installation And Setup Manual

Table of Contents

Advertisement

Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
Entry Delay 2
*36
See *35 above for entries.
Audible Exit Warning
*37
0 = no; 1 = yes
Confirmation Of Arming Ding
*38
Entry 1: 0 = no; 1 = yes, 1-second ding
(ding if armed from wired keypad)
Entry 2: Enter 0-15 from table below.
(ding if armed from RF device)
Entry
Ding at Siren Trigger 2 Output
0
none
1
none
2
none
3
none
4
250mS
5
250mS
6
250mS
7
250mS
8
1 second
9
1 second
#+10
1 second
#+11
1 second
#+12
4 seconds
#+13
4 seconds
#+14
4 seconds
#+15
4 seconds
Power-Up In Previous State
*39
0 = always power-up in a disarmed state
1 = assume the system status prior to
power down
Dialer Programming ( ∗ ∗ ∗ ∗ 40 – ∗ ∗ ∗ ∗ 50)
FIELD
TITLE and DATA ENTRIES

PABX Access Code

*40
Enter up to 6 digits if PABX is needed to
access an outside line. Do not fill unused
spaces.
0–9, # + 11 for '∗', # + 12 for '#', # + 13 for a
pause (2 seconds)
4-4
EXPLANATION
See *35 for explanation.
Warning sound consists of slow continuous beeps until
last 10 seconds, then it changes to fast beeps. Sound
ends when exit time expires.
Entry 1 for each partition selects whether arming
from wired keypads causes siren ding. Confirmation of
arming is 1/2 second external sounder "ding." Ding
occurs when closing reports is sent, or when exit delay
expires.
Entry 2 for each partition selects whether arming from
none
remote RF devices causes siren ding and/or activates
250mS
trigger 2 output; also selects siren ding/trigger
1 second
activation duration (arm = 2 dings of selected duration
4 seconds
with 1 second off between; disarm = 1 ding of selected
none
duration). Ding occurs upon reception of the wireless
arming command.
250mS
1 second
NOTE: If using an option that activates trigger 2,
4 seconds
trigger 2 must be dedicated to only this function; do
none
not assign any other functions to trigger 2.
250mS
1 second
4 seconds
none
250mS
1 second
4 seconds
When the system powers up armed, an alarm will
occur 1 minute after arming if a zone is faulted at that
time.
Note that if the previous state was armed AWAY or
STAY, the system will not respond to sensor changes
for 1 minute, which allows time for sensors such as
PIRs to stabilize.
EXPLANATION
To clear entries from field, press ∗40∗. If fewer than 6
digits need to be entered, exit by pressing [∗], which
advances to the next field.
Call Waiting: If the subscriber's phone service has
"call waiting" (and is not using PABX), enter "*70" ("#
+ 11") plus "# + 13" (pause) as the PABX entry to
disable "call waiting" during control panel calls. If the
subscriber does not have "call waiting" and is not using
PABX, make no entry in this field.