Eim Status Lights; Error Codes (Thermostat & Remote Control) - Honeywell RedLink Installation Manual

Wireless system with equipment interface module
Hide thumbs Also See for RedLink:
Table of Contents

Advertisement

Available languages

Available languages

RedLINK™ Installation Guide (EIM)

EIM status lights

When installation is complete, check the status lights on the equipment
interface module to verify proper operation.
Error codes (thermostat & remote control)
If E1 appears during setup, check error code number (right side of screen):
29
Attempting to connect incompatible wireless devices.
30
Invalid zone number. Zone number must be set to zero (see page 6).
33
Faulty return air sensor. Check wiring or replace sensor as needed.
34
Low signal strength. Move wireless device to a different location and try again.
38
Make sure Connected light on EIM is flashing and you are 2+ feet away from EIM.
System status lights
• Power: EIM is working properly.
• Heat: Heating system is on.
• Cool: Cooling system is on.
• Fan: Fan is on.
Note: If Connected light is flashing, press
button to turn off flashing light, then
CONNECT
recheck status lights.
Wireless status light
• Solid green: EIM is working properly
and communicating with wireless
devices.
• Flashing green: Linking to wireless
devices (light flashes for 15 minutes
after you press
• Solid red: Communication problem.
Check EIM and wireless devices.