2.4 Special Installation

The unit can be hung from or embedded in a wall, but such special installations impose additional limitations on operating
temperatures and other operational factors.
Examine installation methods and the ambient conditions for your installation site, and refer to sections "2.1 Installation Site
Requirements (pg. 12)", "2.2 Installation Conditions (pg. 14)", "2.3 Installation Procedures (pg. 18)" in this manual.
Measurements discussed in this manual assume the following conditions:
• A 100 % white input is supplied.
• Sufficient aging has been completed.
Make all measurements under identical conditions. The aging period required for correct measurement
will be about two and a half hours, depending on the space available at the installation site.

2.4.1 Mounting to fittings

Observe the following guidelines when mounting the unit to fittings.
Notes 2 to 5 apply to all cases of mounting to fitting.
1 When mounting the unit, make sure that there are no objects around it within a distance of 300mm.
2 Any unit deformation/warping occurring as a result of
installation should be less than 4 mm.
3 Never block or cover openings, aside from those shown
as blocked in the illustrations on the following page.
4 The strength of the fittings should be adequate to bear the
weight of the display.
5 Take precautions to avoid sharply bending the power cable.
✩ Operating environment for standard installation
• Ambient Temperature: 0 to 40 °C (example 1)
✩ Operating environment for vertical installation
The operating temperature restrictions for the speaker system (PDP-S29-LR) are the same regardless of installation
position.
Standard installation
Example 1
0 to 40 °C (vertical installation: example 2)
35 mm or
less
Special Installation (Mounting to fittings)
Maximum allowable deformation/warping is 4 mm.
Vertical installation
Example 2
35 mm or less