5
Sub Code
6
Error Message
7
Log Information
Document Version 2011-10
Item
The 6-digit sub code of the relevant hardware (X1YYZZ).
•
•
•
•
Note
A description of the error.
Displays probable causes of the errors and their solutions.
Description
X: Shelf type
–
Physical shelf: " " (blank)
–
Virtual shelf: "*" (asterisk)
1: Shelf number
YY: Slot number
–
KX-TDE100 (Physical slot): 00 to 06
(00: IPCMPR Card Slot/Built-in ESVM card; 01 to 06:
Free Slots)
–
KX-TDE200 (Physical slot): 00 to 11
(00: IPCMPR Card Slot/Built-in ESVM card; 01 to 11:
Free Slots)
–
KX-TDE100/KX-TDE200 (Virtual slot): 01 to 08
(01 to 04: Virtual CO Line Slots, 05 to 08: Virtual
Extension Slots)
ZZ: Port number
–
For optional service cards except OPB3 card:
Port number (01 to 16) will be displayed.
–
For OPB3 card:
Sub slot number (1 to 3) + port number (1 to 4) will be
displayed as follows:
•
Sub slot 1 of OPB3: 11 to 14
•
Sub slot 2 of OPB3: 21 to 24
•
Sub slot 3 of OPB3: 31 to 34
When there is no parameter for slot and port number, YY
and ZZ will be displayed as "00".
Example: Sub code for IPCMPR card = " 10000"
5.1.5 Troubleshooting by Error Log
Installation Manual
165