CM707/701 - InSTAllATIon GuIdE
You have now installed the Programmable Thermostat. For gas boiler applications, the factory system settings will not need to
be changed (for other applications see below). You can now use the
it works to the homeowner.
using the Programmable Thermostat for Specific Applications
Application
Settings
Cycle /Hour
Gas Boiler (<30kW)
6
Oil Boiler
3
Thermal Actuator
12
Zone Valve
6
Electric Heating
12
(resistive load 3-5A)
using the Special Features of the Thermostat
Special Feature
desctiption
Summer/Winter Auto
This feature moves time automatically on the last Sunday of March
time change
and the last Sunday of October. The feature is factory enabled.
Optimisation
The thermostat will adjust the start time in the morning/afternoon
(Variable Start Time)
so the desired temperature is reached by the start of the program
period. The system will restrict the start time to a max of 2 hours.
Scheduled
If the installation requires scheduled maintenance and the user
Maintenance Alert
needs to be reminded that the service is due the parameter value
Period
can be set to the required number of months (1-48). When the preset
period expires the CM701/CM707 will display the 'SERVICE' icon.
Entering the Installer Mode
1.
oFF
Press the
button.
2.
PRoGRAM
Press and hold the
button and the two
or
buttons together.
3.
The unit will display the first parameter of installer
parameter group category 1 (from Parameter No. 1 to 20).
4.
Press the
or
button to change the factory setting.
The display will flash indicating that a change has been
made.
5.
Press the green
button to confirm the change. The
display will stop flashing.
6.
Press the
button to go to the next parameter.
7.
PRoGRAM
Press the
button to go to Installer parameter
group category 2 (from Parameter No. 1 to 5).
8.
AuTo
MAn
To exit installer mode, press the
,
button.
uSER GuIdE
to program the unit and demonstrate how
What to change
Minimum ON
Note: All parameters listed below belong to category 2
– system parameters (see Installer Parameter Table)
time
1
No changes required
4
Set 1:Ot parameter to 4
Set 2:Cr parameter to 3
1
Set 2:Cr parameter to 12
No changes required
1
1
Set 2:Cr parameter to 12
Enable/disable this feature
To enable: Set parameter 3:
tC (category 1) to 1.
To enable: Set parameter 8:
OP (category 1) to 1.
Set parameter 19 to the
required value to enable
maintenance alert. Value set
to zero disables the function.
1
2
3
4
5
6
7
DATE/
DAY
MANAUTO
COPY
DAY
1..4
1
2
3
4
5
6
7
DATE/
DAY
COPY
DAY
1 2
oFF
or
1..4
2

Installer Parameters Table

Parameter
Category 1 Parameters - Programmable Thermostat Settings
AM-PM / 24hr Display
Reset Time/ Temp
Program
Auto Summer/Winter
Time Change
LCD Backlight
Upper Temp Limit
Lower Temp Limit
Optimisation
Temperature Offset
Proportional Band
Width
Scheduled Maintenance
Alert Period (months)
Reset Parameters to
Factory Defaults
Category 2 Parameters - System Settings (press PRoGRAM
Minimum boiler ON
time
Cycle Rate
Pump Exercise
AUTO
notes:
Always remember to press the green
MAN
1
the Installer Set-Up Mode press the
OFF
System Commissioning
To enter the diagnostic mode press the
mode. Next press and hold the
will be available on the display: model ID, date code (WW/YY) and checksum. To view this info press the
"Manufactured for and on behalf of the Environment and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37,
Switzerland by its Authorised Representative Honeywell International Inc."
AUTO
MAN
Honeywell Control Systems ltd.
2
OFF
Arlington Business Park,
Bracknell
Berkshire
RG12 1EB
Technical Help Desk: 08457 678999
www.honeywelluk.com
Parameter
Factory default Settings
no.
Display
Description
1:CL
12
12 hr – AM/PM clock display
format
2:rP
1
Time / Temp profile set to factory
default
Changes to 0 when one of the
time/temp profiles are changed
3:tC
1
Auto Summer/Winter Time
Change enabled
5:bL
1
Backlight enabled
6:UL
35
5°C Lower Temp. Limit
7:LL
5
No temperature offset
8:Op
0
Optimisation disabled
12:tO
0
Proportional band of 1.5 degree
13:Pb
1.5
All settings at factory defaults.
19:SP
0
Scheduled Maintenance Alert
Period disabled
20:FS
1
Changes to 0 when one of the
parameter is changed
to access this category)
1:Ot
1
1 minute minimum ON time
2:Cr
6
6 cycles per hour (cph)
5:PE
0
Pump exercise disabled
button to confirm that you want to store the new Installer Set-Up setting. To exit
AuTo
MAn
or
button.
oFF
button then press and hold the
and
buttons together. The unit will hold the relay on for 5 minutes and the following information
42010938-007 R1
© 2006 Honeywell International Inc.
optional Settings
Display
Description
24
24 hr clock display format
0
Time / Temperature are as
programmed
1
To restore the factory profile
set to 1
0
Auto Summer/Winter Time
Change disabled
0
Backlight disabled
21-34
21°C to 34°C adjustment in
1°C steps
6-20
6°C to 21°C adjustment in
1°C steps
1
Optimisation enabled
-3 to +3
-3°C to +3°C adjustment in
0.1°C steps
1.6 to 3.0
1.6°C to 3.0°C adjustment in
0.1°C steps
0 to 48
0 to 48 months adjustment in 1
month steps
0
Settings are as modified above
1
To restore the factory profile set to 1
2 to 5
Selection of 2, 3, 4 or 5
minutes minimum ON time
3,9,12
Selection of 3, 9 or 12 cph
1
Pump exercise enabled
button for 5 sec. The unit will enter the user settings
or
button.

Advertisement

loading

This manual is also suitable for:

Cm701