Cleaning, Care & Maintenance
Note: Always switch off and disconnect the appliance from the power supply before
cleaning.
Always allow the appliance to cool before cleaning.
Remove the inner bowl and wash in warm, soapy water. Do not use harsh abrasive cleaners or
1.
products that are not recommended for use on non-stick coatings.
Rinse and dry thoroughly.
2.
Clean the exterior of the rice cooker with a damp cloth.
3.
Ensure the heating plate is clean and free of food or other
4.
debris that could interfere with the cooking process.
Dry the heating plate thoroughly before use.
5.
Remove the water collector from below the lid hinge by
6.
pulling outwards [Fig. 1]. Discard the water collected after
each use.
Clean and replace the water collector.
7.

Troubleshooting

Fault
The unit is not
working
Rice is not thoroughly
cooked
Rice is overcooked
3
Probable Cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
The bowl is not in contact with the
heating plate
The bowl is not in contact with the
heating plate
The bowl has become deformed
Not enough water
Too Much water
Fig. 1
Action
Check the unit is plugged in correctly and
switched on
Call BUFFALO agent or qualified technician
Replace the plug fuse
Check power supply
Call BUFFALO agent or qualified technician
Realign bowl
Reposition bowl
Replace bowl
Increase the amount of water used
Decrease the amount of water used