Power Factor Control Circuit - Hitachi RAS-60YH5 Service Manual

Room air conditioner
Hide thumbs Also See for RAS-60YH5:
Table of Contents

Advertisement

12. Power Factor Control Circuit

Power factor is controlled to almost 100%. (Effective use of power)
With IC in ACT module, control is performed so that input current waveform will be similar to waveform of input
voltage
I (input current)
input voltage
V (input voltage)
Effective
input current
voltage
area
Effective
voltage area
Invalid power area
(Even if voltage is applied. current does not flow)
* Assuming the same current capacity (20A), power can be used about 10% effective, comparing with curent use
(power factor of 90%), and maximum capacity is thereby improved.
– 91 –

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rac-60yh5

Table of Contents