Honeywell CL20AE Owner's Manual

Honeywell CL20AE Owner's Manual

Portable evaporative air cooler
Hide thumbs Also See for CL20AE:

Advertisement

Portable Evaporative Air Cooler
OWNER'S MANUAL
Read and save these instructions before use
Model: CL20AE
Voltage rating: 220 - 240V~50Hz
For product enquiry or support contact :
110V~60Hz
CUST OMER CARE : 1300 7108 60
Power rating: 230W
www.honeywellaircoolers.com
Made in China.
e-mail: info@honeywellaircoolers.com

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell CL20AE

  • Page 1 Portable Evaporative Air Cooler OWNER’S MANUAL Read and save these instructions before use Model: CL20AE Voltage rating: 220 - 240V~50Hz For product enquiry or support contact : 110V~60Hz CUST OMER CARE : 1300 7108 60 Power rating: 230W www.honeywellaircoolers.com Made in China.
  • Page 2 This page is intentionally left blank...
  • Page 3: Table Of Contents

    INDEX Read all instructions carefully before setting up and operating the unit, and please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to setup, operate, maintain, and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty.
  • Page 4: Thank You

    THANK YOU THANK YOU! Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum cooling performance from your unit, fill the water tank with water & ice (if available) to increase its cooling power. The unit should be positioned in a location that will create a 'flow through' air effect.
  • Page 5: User Tips

    USER TIPS COOL ~ EFFICIENT ~ NATURAL Evaporative air cooling is the natural way of cooling, similar to a breeze blowing across a lake. This breeze drops the temperature and has a relaxing cooling effect. The evaporative air cooler cools the air by means of the evaporation of water. When water evaporates into the air, the result is a mixture of air and water molecules.
  • Page 6 USER TIPS The recommended maximum relative humidity level is 60% or The recommended maximum relative humidity level is 60% or less, which allows a noticeable temperature decrease. The less, which allows a noticeable temperature decrease. The temperature decrease will be greater in drier climates because temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low.
  • Page 7: Safety Rules

    SAFETY RULES READ AND SAVE THESE INSTRUCTIONS: When using electrical appliances, basic safety precautions should always be followed: • Your unit runs on 220/127 Volt AC, 60 Hz current. Check the household voltage to ensure it matches the appliance's rate 220-240 Volt AC, 50Hz specification.
  • Page 8 SAFETY RULES • DO NOT attempt to repair or adjust any electrical or mechanical functions of the cooler, as this may void the warranty. • DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage. •...
  • Page 9: Parts Description

    PARTS DESCRIPTION Control Panel Vertical Louvers Side Handle (Manual Movement) Horizontal Louvers Front Panel (Automatic with SWING Button) Water Level Indicator Left Side Panel Remote Control Front Cover Ornament Remote Control Holder Power Cord & Plug Right Side Panel Casters Water Fill Door Ice Compartment Lid Drainage Tube / Cap...
  • Page 10: Use & Operation

    USE & OPERATION CONTROL PANEL Mode Button Swing Control High MODE SWING Speed Control SPEED TIMER Cool Sleep POWER Timer Control Power Button...
  • Page 11: Function Buttons

    USE & OPERATION FUNCTION BUTTONS POWER Press the POWER button to turn the unit on. To turn the unit off, press the button again. The cooler will start automatically POWER at medium speed. After a few seconds the speed will switch to low.
  • Page 12 USE & OPERATION SWING Press the SWING button. The indicator light will come on and LOUVERS MOVEMENT the louvers will begin to move from right to left automatically. Manually adjust the horizontal louvers to change vertical airflow. TIMER Press the TIMER button until the indicator light moves to your desired time.
  • Page 13: Room Cooling And Humidifying

    USE & OPERATION ROOM COOLING AND HUMIDIFYING When the water regulator is set to MIN, the water pump Water Regulator distributes a minimal amount of water to the honeycomb media. This results in less water evaporation and reduces cooling effect. Thus, reducing the humidity inside the room. When the water regulator is set to MAX, the water pump distributes the maximum amount of water to the honeycomb media.
  • Page 14: Remote Control

    USE & OPERATION REMOTE CONTROL Power: On / Off Speed: Speed: Low / Medium / High / Sleep ON/OF Mode: Controls cooling or fan option MODE TIMER SWING Swing: Controls the motion of the louvers SPEED Timer: Controls timer function for automatic shut off Evaporative Air Cooler Note : Remote control and holder are packed inside the top ice loading compartment, during delivery.
  • Page 15: Fill Water

    USE & OPERATION FILL WATER Open the Water Fill Door located below the Remote Control Holder on the unit. The water tank of the unit holds up to 20 litres of water. Water level display window is located on the front of the unit. Refill the water tank when water level is low.
  • Page 16: Cleaning & Maintenance

    CLEANING & MAINTENANCE WARNING • Before cleaning the unit, switch it to the off position and remove the plug from the power socket. • To clean the outside, use a damp cloth to remove dirt and dust. • Never use detergents, corrosive elements or any chemicals to clean this product. •...
  • Page 17 CLEANING & MAINTENANCE CLEANING THE CARBON / DUST FILTER • Turn off the unit, and unplug the power cord from wall outlet. Knobs • Rotate the unit facing the back panel, and locate the knobs to remove back grill. • Press both the knobs (see fig.) and gently pull out the back grill, untill it is completely removed.
  • Page 18: Troubleshooting Guide

    TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION No discharge of air Cord is not plugged in. Make sure power cord is plugged in and the supply switch in ON. Power is not on. Try to turn the unit ON by pressing buttons on control panel or remote control.
  • Page 19 TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION The unit does not respond Remote control batteries. Check batteries, Replace if needed. Try to operate using the control panel. Damaged PCB Try with remote control. If the unit responds, PCB board fasteners may be loose. Contact service centre.
  • Page 20: Technical Specifications

    TECHNICAL SPECIFICATIONS MODEL NO. CL201AE Voltage 220 - 240V 50Hz Frequency Wattage 200 Watts Water Tank Capacity 20 Litre Cooling Media Honeycomb Product Dimension 480(L) x 370(W) x 835(H) mm 10.6 Kg Net Weight 0.91A Current 0.011m /hour Humidifier 0.18 Refrigerant efficiency ELECTRICAL WIRING DIAGRAM COOL...
  • Page 21 March 2010 Tsim Sha Tsui East, Kowloon, Hong Kong © 2010 AirTek International Corporation Limited tel: +852 2559-5522 The Honeywell Trademark is used under license from Honeywell International Inc. fax: +852 2559-0699 Honeywell International Inc. makes no representation or e-mail: info@honeywellaircoolers.com warranties with respect to this product.

Table of Contents