Problem
No live feed coming from
camera
Battery warning appears
Count accuracy unreliable
Integrated counter low battery
warning appears on screen
The "+" symbol appears after
the on-screen distance mea-
surement
SOS blinking on Power Key
LED
14 – English
Troubleshooting
Probable Fault
No power to SeeSnake
Connection faulty
18 V Li-Ion battery low
18 V Li-Ion battery low
Integrated counter settings incor-
rect for reel or cable
Counting from the wrong ze-
ro-point
Integrated counter battery dead
or near-dead
Physical cable measurement has
exceeded the cable parameter in
settings.
No video signal
Solution
Check power is correctly plugged in.
Check alignment and pins of connection from CS6 to the
SeeSnake Reel.
Recharge battery. Switch to AC power.
Recharge battery. Switch to AC power.
Verify the settings are correct for the SeeSnake cable
length, cable diameter, and SeeSnake reel.
Confirm measurement from the intended zero-point.
Reset zero-point using the Zero key
Replace 3 V battery in the integrated counter.
Verify the actual length of installed cable and reset the
SeeSnake reel and cable settings according to the reel's
operator's manual.
Check SeeSnake system cable connection.
.