16
en | RADION receiver OP
Communication error state:
The receiver enters a communication error state when, during power up, it does not establish
a link with the control panel, or has been in an idle state for more than 30 sec without
communication. Another cause for a communication error state is an invalid address switch
setting (0, or 9).
LED condition
3-pulse flash: A 3-pulse signal, followed by a
short delay at the end of the 3
(Communication error)
Trouble state:
The receiver enters a trouble state when an internal self-test detects a failure. Another cause
for the receiver entering into a trouble state would be if the receiver detects radio frequency
interference failure.
LED condition
Continuous fast flash: A continuous pulse
between On and Off states (Trouble state)
Maintenance state
The receiver enters a maintenance state when the address switch settings are set between
switch 5 – switch 8.
LED condition
Continuous Flash: A continuous pattern of
short off time, followed by long on time.
Off state
Indicates there is a power failure to the receiver. Check the wire connections for proper
wiring.
3.4

Specifications (RFRC-OPT)

Housing Dimensions (H x W x D)
Power/Voltage
Maximum Current Draw
Operating Environment
02.2014 | 01 | F.01U.261.835
State description
Indicates the receiver has experienced a
pulse
communication failure. This error could be a
rd
result of either:
A communication failure between the
control panel and receiver, or
An invalid address switch setting
State description
Indicates the receiver is in a trouble
state, experiencing a radio frequency
interference failure
A communication failure with internal
hardware components within the
receiver
State description
Indicates the receiver is in Maintenance
Mode.
139.7 mm x 209.6 mm x 31.8 mm (5.5 in x
8.25 in x 1.25 in)
12 VDC nominal
100 mA
Functional range: -10°C to +49°C (+14°F to
+120°F)
EN 50130-5 Class II only: -10゚C to 40゚C (+14゚
F to +104゚F