Overview

The RE005EV2 RF Arming Kit is designed to provide a convenient ON/OFF Control for the Solution16 alarm panels. Provision is also made for the control of up to two (2) external devices via on board relays.

Features

  • Code Hopping RF security ( 4.2 billion combinations)
  • Simple installation
  • Superheterodyne receiver (less interference)
  • Robust attractive keyfobs
  • Two onboard programmable relays

Wiring and Connections

Installation and Set up

  1. Select a location to install the ABS bulkhead case of the receiver which is non metallic. Metal objects close to the receiver may affect range.
  2. Connect wiring to Solution 16 keypad bus.
  3. In the installer programming of the Solution 16 set;
    Location 666 = Option 1 enabled
    Location 665 = Option 8 enabled if horn speaker beeps are required.
  4. The supplied fobs are already learned to the RE005EV2 with both relays set for momentary operation. If however a different relay set up is required then the fobs will need to be deleted and learned again as below.
    TO DELETE FOBS - Press and hold the Learn/Delete switch. Note that the LED will light and then extinguish after 4 seconds. The EEPROM memory is now erased. Individual fob deletion is not possible.
    TO LEARN FOBS - Press the Learn/Delete switch once. Note that the LED will flash rapidly. Now press the button on the FIRST fob to be learned corresponding to the relay functions required ( see below). The LED will come on solid whilst receiving the transmission and then flash once to confirm learning. Repeat for additional fobs ( maximum 21). It is not important which button is pressed on fobs learned after the FIRST as the relay functions are set by the FIRST learned fob.

Relay Programming
Button 1 = Both outputs momentary
Button 2 = Output 1 toggling, Output 2 momentary
Button 3 = Output 2 toggling, Output 1 momentary
Button 4 = Both outputs toggling

  1. Press the Learn/Delete button once when finished learning fobs. Note that if no RF activity occurs the RE005EV2 will leave learn mode automatically after 20 seconds.
  2. Test Operation.

Note: The button functions are fixed and cannot be changed as per the diagram below.
Relay Button Functions

Panic Function: The fob can generate a panic on the Solution panel. Holding down buttons 1 and 2 for a period of 2 seconds will cause a panic alarm.

Specifications

Receiver
Operating Voltage 9 - 15VDC
Current Consumption 9mA Standby
43mA Both relays operating
Relay Rating SPDT 1Amp Maximum carry @ 12VDC
Reverse Polarity protection Yes. Diode
Operating Frequency 433.92mhz
Receiver Type Superheterodyne AM ASK
Bandwidth 250khz
Antenna 165mm solid core insulated wire
Fob Storage EEPROM Maximum 21 Fobs
Transmitter (Fob)
Operating Voltage 3V Lithium Battery CR2032
Operating Frequency 433.92mhz
Bandwidth 260khz
Tuning SAW resonator locked
Channels 4
Weight 33g including battery
Visual Indicator Blue LED

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Bosch RE005EV2 - RF Arming Kit Manual

Advertisement

Need Assistance?

Do you have a question about the RE005EV2 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents