Performance Data Sheet - GE AvantaPure Operation Manual

Avantapure professional series water treatment system
Table of Contents

Advertisement

Model
Rated Service Flow (gpm)
Pressure Drop at Rated
Service Flow Rate (psi)
Rated Capacity
(grains @ lb of salt)
Rated Efficiency
(grains/lb Salt @ lb of salt)
Maximum Flow Rate During
Regeneration (gpm)
General Technologies C110
Ion Exchange Resin (cu ft)
Backwash - GPM
Rapid Rinse/purge - GPM
Operating Pressure:20 -125 psi or 1.4 – 8.8 kg/Centimeter
Temperature: 35 - 100° F or 1.6 – 38° C
Acceptable Salt Type: Sodium Chloride – Pellet or solar salt for water
softeners
These water softener systems have been tested by WQA and conform to NSF/ANSI 44
for specific performance claims as verified and substantiated by test data. The rated salt
efficiencies above were also determined in accordance with NSF/ANSI 44 and are only
valid at the salt dosage referenced above. An efficiency rated water softener is a demand
initiated regeneration (DIR) softener which also complies with specific performance
specifications intended to minimize the amount of regenerant brine and water used in its
operation. Efficiency rated water softeners shall have a rated salt efficiency of not less
that 3350 grains of total hardness exchanged per pound of salt (based on NaCl
equivalency) (477 grams of total hardness exchanged per kilogram of salt), and shall not
deliver more salt than its listed rating. The rated efficiency of the water softener, the salt
dosage at that efficiency, the capacity at that salt dosage and that of the efficiency is only
valid at the stated salt dosage. Efficiency is measured by a laboratory test described in
NSF/ANSI 44. The test represents the maximum possible efficiency the system can
achieve. Operational efficiency is the actual efficiency achieved after the system has
been installed. It is typically less than the efficiency due to individual application factors
including water hardness, water usage, and other contaminants that reduce the water
softener's capacity. These systems are not intended to be used for treating water that is
microbiologically unsafe or of unknown quality without adequate disinfection before or
after the system. Refer to the system Installation and Service Manuals for set-up and
programming instructions.
Contact your local dealer for parts and service. See your owner's manual for warranty
information.
Important Notice: For conditions of use, health claims certified by the California
Department of Public Health and replacement parts, see product data sheet.
Iowa Requirement:
WATER SOFTENER PERFORMANCE DATA SHEET
Avantapure
269-869-100-1040
10.0
8.0
10,600 @ 2.47
23,090 @ 9.06
27,918 @ 13.18
4,288 /lb. salt @ 2.47 lbs.
2.8
1.0
2.7
2.8
2
, Operating
PENTAIR Residential Filtration, LLC
5730 North Glen Park Road Milwaukee, Wisconsin 53209
PHONE: (262)-238-4400
3
Avantapure
269-869-125-1047
13.5
15.0
14,922 @ 3.0
32,503 @ 11.0
39,299 @ 16.0
4,974 /lb. salt @ 3.0 lbs.
2.8
1.25
2.7
2.8
All Systems above tested at 35psi +/- 5 psi, pH of
7.5 +/- 0.5, Capacity Testing Flow Rate = 50% of
the rated service flow rate for the various size
systems.
Seller:
_______________________
_______________________
________________
Date:
_______________________
__
Buyer:
_______________________
_______________________
________________
Date:
_______________________
__
7/16/10
Avantapure
269-869-150-1054
12.5
15.0
17,906 @ 3.6
39,003 @ 13.2
47,158 @ 19.2
4,974 /lb. salt @ 3.6 lbs.
2.8
1.5
2.7
2.8
Tested and Certified by the WQA
against NSF/ANSI Standard 44 &
372 for softener performance &
"lead free" compliance
The Avantapure 269 valve has been
Tested and Certified by the WQA to
NSF Std. 61 section 8 for Material
Safety Only