Overflow Line Connection; Electrical Connection - GE AvantaPure Operation Manual

Avantapure professional series water treatment system
Table of Contents

Advertisement

Note: Once the tubing has been pushed into the nut it
cannot be pulled out. The nut will need to be removed.
See Figure 14 for correct assembly.
6.
Hand tighten the nut until the connection is tight.
Figure 14

Overflow Line Connection

In the event of a malfunction, the salt TANK OVERFLOW will
direct "overflow" to the drain instead of spilling on the floor.
This fitting should be on the side of the cabinet. Most tank
manufacturers include a post for the tank overflow
connector.
To connect the overflow line, locate the tubing connector
on side of tank, Figure 15. Attach length of 1/2-inch
(1.3-cm) I.D. tubing to fitting and run to drain. Do not
elevate overflow line higher than overflow fitting.
Do not tie into drain line of control unit. Overflow line must
be a direct, separate line from overflow fitting to drain,
sewer or tub. Allow an air gap as per drain line instructions.
Figure 15
Overflow Fitting
Drain Tubing
Secure hose in place
Air Gap
Drain

Electrical Connection

WARNING: This valve and control are for
dry location use only, unless used with a
Listed Class 2 Power Supply suitable for
outdoor use.
Note: There are no user serviceable parts in the AC
adaptor, motor or the control board.
All controllers operate on a 12-volt alternating current
power supply. This requires use of the Pentair Water
supplied AC adapter. A variety of AC adapters are available
for different applications. These AC adapters are available
from your supplier. They include:
Input
AC Adapter
Voltage
Standard
120V
wall-mount
60 Hz
120V
Outdoor rated
60 Hz
120 VAC AC Adapters:
Make sure power source matches the rating printed on the
AC adapter.
Note: The power source should be constant. Be certain
the AC adapter is not on a switched outlet. Power
interruptions longer than 8 hours may cause the
controller to lose the day and time settings. When power
is restored, the day and time settings must be re-entered.
Controller Location
The controllers are designed to be mounted on the valve or
attached to a flat surface. Installations that do not provide
easy access to the valve can have the controller mounted
for remote operation.
A remote mount connection, PN 1256257, is available for
the AvantaPure Series controller.
15
Application
Part Number
Standard indoor
1000811
application
UL listed for
outdoor
1235448
installations