Power Supply Housing; Fan Motor Assembly - GE ZV800SJSS Technical Service Manual

36-in. chimney vent hood
Hide thumbs Also See for ZV800SJSS:
Table of Contents

Advertisement

Fan Motor Assembly

The fan motor assembly is located inside the fan
motor housing above the canopy. The fan motor
has 4 speeds and utilizes a start/run capacitor. Fan
speeds are selected at the push-button assembly
located in the visor.
To remove the fan motor assembly:
Caution: This procedure requires that the cooking
unit below the hood be protected from any possible
damage.
1. Disconnect power to the vent hood.
2. Remove the visor. (See
3. Remove the light shield. (See
4. Remove the duct cover. (See
5. Remove the power supply housing cover. (See

Power Supply Housing

6. Remove the 4 Phillips-head screws that hold
the lower electrical component cover in place.
Remove the cover.
7. Remove the bottom wire retention clamp.
8. Disconnect the push-button assembly ribbon
connector from the power control board.
9. Unplug the fan motor wiring connector from
the power control board. Remove the fan motor
ground wire.
Fan Motor
Ribbon
)
Visor.
Light Receptacle.
.)
Duct Cover
.)
Ground Wire
Wire Retention Clamp
10. Remove the 4 Phillips-head screws that hold the
inner bracket to the canopy. Lower the inner
bracket.
)
11. Remove light wiring and split-ring grommets
from inner bracket.
– 17 –
Inner Bracket
(Continued Next Page)